Performance Evaluation of Viscoelastic and Friction Passive Damping System in Steel Structures
نویسندگان
چکیده مقاله:
Additional dampers are employed in order to decrease the dynamic response of structure against the earthquake and wind loading recently. In this study, two types of systems related to waste of inactive energy, i.e. frictional damper which is categorized in dampers dependent on movement and viscoelastic damper which is categorized in dampers dependent on velocity, in making steel structures resistant are investigated and evaluated. Results of structures with dampers (viscoelastic damper, friction damper and combination of both dampers) were compared with the results of structures without damper. Increasing trend in dissipating energy was observed. Then, the behavior of these dampers in frames of 4, 8 and 12 stories was studied by modeling the damper directly. The analyses were conducted via nonlinear time history technique and by using earthquake records (near fault and far fault) scaled with peak acceleration and SAP 2000 14.2.2 software. The results indicate the appropriate function of the selected dampers in controlling and decreasing the seismic responses of the structure. Given that in frictional dampers the maximum force created in the damper is specified, the use of this damper in resistance building of structures is very effective especially by considering the limitation of structure capacity.
منابع مشابه
performance evaluation of viscoelastic and friction passive damping system in steel structures
additional dampers are employed in order to decrease the dynamic response of structure against the earthquake and wind loading recently. in this study, two types of systems related to waste of inactive energy, i.e. frictional damper which is categorized in dampers dependent on movement and viscoelastic damper which is categorized in dampers dependent on velocity, in making steel structures resi...
متن کاملperformance evaluation of viscoelastic and friction passive damping systems in vibration control of tall buildings
this paper provides a comparison of the maximum inter-story drifts and tip acceleration of both a 16 and 30 stories building each with different structural systems; hybrid r.c moment frame with shear walls and hybrid steel frame with shear walls and x bracing which are equipped by passive dampers. each of the building models were analyzed as fully non-linear structures for variety of dampers pl...
متن کاملModeling of Unsteady Friction and Viscoelastic Damping in Piping Systems
In real systems, the phenomena, such as pipe-wall viscoelasticity, unsteady friction or fluid structure interaction induce additional damping and dispersion of transient pressure waves than that defined by classical waterhammer. In this paper, unsteady friction models and viscoelastic damping models will be presented and a theoretical formulation of the viscoelastic damping in piping systems wi...
متن کاملnon-linear study of various slit shear walls in steel structures
seismic retrofit strategies have been developed in the past few decades following the introduction of new seismic provisions and the availability of advanced materials and methods. it can be observed that new approaches to deal with more lateral forces are more innovative and more energy absorbent. in line with this, there is a growing trend toward the use of steel shear walls as a system with ...
15 صفحه اولEarthquake Response of Adjacent Structures with Viscoelastic and Friction Dampers
We study the seismic response of two adjacent structures connected with a dry friction damper. Each of them consists of a viscoelastic rod and a rigid block, which can slide without friction along the moving base. A simplified earthquake model is used for modeling the horizontal ground motion. Energy dissipation is taken by the presence of the friction damper, which is modeled by the set-valued...
متن کاملperformance of biological system and advanced oxidation processes (aop) treating antibiotic production industrial wastewater
در این مطالعه، عملکرد دو سیستم اکسیداسیون شیمیایی پیشرفته و یک سیستم بیولوژیکی برای حذف آموکسی سیلین در فاضلاب های سنتزیدر غلظت های مشابه با موارد صنعتی مورد بررسی قرار گرفته شدند. مطالعه انجام شده دارای سه بخش متفاوت اکسیداسیون با ازن و اشعه uv، اکسیداسیون با استفاده از نانو فتوکاتالیست tio2 و استفاده از بیوراکتور هوازی لجن فعال با جداکننده های فیزیکی می باشد. در هر بخش، متغیر های متفاوتی متنا...
15 صفحه اولمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 5 شماره 2
صفحات 1- 23
تاریخ انتشار 2015-06-30
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023