Performance characteristics of three automated immunoassays for thyroid hormones
نویسندگان
چکیده مقاله:
Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the results of this method with those of radioimmunoassay ( RIA) [immunoradiometric (IRMA) for TSH] and Elisa. Methods: Fasting serum from 112 hypo, hyper and euthyroid patients were used to evaluate the minimum detectable concentration, intra- and inter-assay precisions for TSH, FT4, T3, linearity for TSH assay and method comparison study. Results: Within the analytical range tested, intra-assay coefficient of variation was < 2.3% for TSH, 2.3% for FT4 and 7.8% for T3. The inter-assay coefficient of variation was < 2.9% for TSH, 2.5% for FT4 and 12.3% for T3. The measurement of diluted sera indicated a desirable percentage of recovery for TSH. No correlation was found between Elecsys 2010 and Elisa /IRMA for TSH. The comparison of results of the Elecsys ECLIA assay with those of Elisa and RIA for T4 were: T4 (ECLIA) = -0.612+0.999, T4 (Elisa, r= 0.88) and T4 (ECLIA)=0.642+0.942 T4 (RIA, r=0.957), while ECLIA assay with Elisa and RIA for T3 were: T3 (ECLIA)= 0.242+0.908 T3 (Elisa, r=0.8) and T3 (ECLIA) = -0.029+1.01 T3 (RIA, r=0.957). Conclusion: The results show that Elecsys 2010 is an automated reliable, efficient and technically excellent instrument to use in the measurement of serum TSH, T4 and T3.
منابع مشابه
performance characteristics of three automated immunoassays for thyroid hormones
background: since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. we performed an analytical evaluation of the new electrochemiluminescent immunoassay (eclia) for serum tsh, ft4 and t3 in the elecsys 2010 immunoassay system and compared the resu...
متن کاملPerformance characteristics of three automated immunoassays for thyroid hormones.
BACKGROUND Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resul...
متن کاملCOMPARISON OF THREE AUTOMATED IMMUNOASSAYS FOR RUBELLA IgG
Introduction: The Serology section of the Microbiology Department performs Rubella immunity screening mainly from antenatal patients and staff health clinics, with a small number of tests being performed for the diagnosis of Rubella infection. Since the implementation of the NSW Department of Health Circular 2003/91 “Occupational Screening and Vaccination against Infectious Diseases”, the numbe...
متن کاملPerformance characteristics of eight estradiol immunoassays.
Measurement of estradiol is useful in assisted reproduction, evaluation of infertility, menopause, and male feminization. The analytic performance of 8 estradiol immunoassays was evaluated. The imprecision and accuracy of the Access, ADVIA Centaur, ARCHITECT i2000, AutoDELFIA, Elecsys 2010, IMMULITE 2000, and Vitros ECi estradiol assays (see text for proprietary information) were evaluated by u...
متن کاملAutomated separation for heterogeneous immunoassays
Beside general requirements for modern automated systems, immunoassay automation involves specific requirements as a separation step for heterogeneous immunoassays. Systems are designed according to the solid phase selected: dedicated or open robots for coated tubes and wells, systems nearly similar to chemistry analysers in the case of magnetic particles, and a completely original design for t...
متن کاملassessment of the park- ang damage index for performance levels of rc moment resisting frames
چکیده هدف اصلی از طراحی لرزه ای تامین ایمنی جانی در هنگام وقوع زلزله و تعمیر پذیر بودن سازه خسارت دیده، پس از وقوع زلزله است. تجربه زلزله های اخیر نشان داده است که ساختمان های طراحی شده با آیین نامه های مبتنی بر نیرو از نظر محدود نمودن خسارت وارده بر سازه دقت لازم را ندارند. این امر سبب پیدایش نسل جدید آیین نامه های مبتنی بر عملکرد شده است. در این آیین نامه ها بر اساس تغییرشکل های غیرارتجاعی ...
15 صفحه اولمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 3 شماره None
صفحات 400- 404
تاریخ انتشار 2012-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023