PERCUTANEOUS TRANSTHORACIC BIOPSY USING TRU-CUT NEEDLE

نویسنده

  • FARHOOD SAREMI From the Department of Radiology, Vali-Asr Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Islamic Republic of Iran
چکیده مقاله:

Biopsies of thoracic lesions guidance. 22 of the 1 12 lesions were mediastinal and 83 were pleuroparenchymal. A large-bore 14-gauge Tru-cut needle was used in all patients. Adequate specimens for histologic examination were obtained in 98%. The overall accuracy was 91 % with 9% false negative and no false positive diagnoses. Despite the large size of the needle, the total number of complications remained low ( 17%). Pneumothorax was detectable in 1 1.5% of biopsies and hemoptysis in 2.6%. Tru-cut needle is suitable for biopsying chest wall tumors, pleural based lesions, superior sulcus tumors, and accessible mediastinal lesions. The instrument is useful not only for diagnosing malignacy but also for determining specific malignant cell types and diagnosing benign disorders.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

percutaneous transthoracic biopsy using tru-cut needle

biopsies of thoracic lesions guidance. 22 of the 1 12 lesions were mediastinal and 83 were pleuroparenchymal. a large-bore 14-gauge tru-cut needle was used in all patients. adequate specimens for histologic examination were obtained in 98%. the overall accuracy was 91 % with 9% false negative and no false positive diagnoses. despite the large size of the needle, the total number of complication...

متن کامل

Transjugular liver biopsy using Tru-cut biopsy needle: KEM experience.

BACKGROUND AND AIM Transjugular liver biopsy is accepted procedure in patients in whom percutaneous liver biopsy is contraindicated. We report our experience with this procedure, its indications, efficacy and safety in Indian population over 5 years. MATERIAL & METHODS A retrospective study of 145 consecutive patients who had undergone transjugular liver biopsy from May 2002 to Nov. 2007 was ...

متن کامل

Comparison of the Tru-cut biopsy needle with the Abrams punch for pleural biopsy.

In a prospective study pleural biopsy specimens obtained with a Tru-cut needle were compared with those obtained with an Abrams pleural biopsy punch from 36 patients in Zimbabwe judged to have an effusion of at least 1.5 litres; one patient had two biopsies. Both instruments were used on each patient, the Abrams punch being followed by the Tru-cut needle. There were no serious complications. Th...

متن کامل

A randomised study on the efficacy and safety of an automated Tru-Cut needle for percutaneous liver biopsy.

BACKGROUND We studied whether the theoretical advantages of a spring-loaded liver biopsy needle exist in clinical practice and if so if they are dependent upon the experience of the physician performing the biopsy. METHODS In a stratified randomised study we enrolled 215 consecutive patients to compare the safety and efficacy of a new automatic biopsy gun (Acecut) with that of a standard Tru-...

متن کامل

'Tru-Cut' needle biopsy of the liver: importance of the correct technique.

In order to determine which technique would provide adequate tissue for histological examination when the 'Tru-Cut' needle is used for liver biopsy, the livers of cadavers were biopsied by a single operator, under direct vision, using a 'Tru-Cut' needle. The modified breast biopsy technique either preceded or followed one of two alternative methods, one of which was recommended by the manufactu...

متن کامل

Automated tru-cut imaging-guided core needle biopsy of canine orbital neoplasia. A prospective feasibility study

The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultr...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 2  شماره 3

صفحات  179- 184

تاریخ انتشار 1988-11