Background: The radiation doses resulting from diagnostic X-ray examinations are routinely measured in terms of entrance surface dose (ESD) and effective dose (ED). In this study, for the purpose of radiation protection, the radiation doses received from Digital chest X-ray examination were evaluated in terms of ESD and ED. Material and Methods: The ED was calculated by using the MCNP Monte Carlo code and an adult hermaphrodite mathematical phantom. The effects of both operating high voltage and projection geometry on the effective dose were investigated. The absolute values of the ED were calculated for digital and conventional Posterior-Anterior (PA) and Lateral (LAT) projections of chest radiography. Results: The results show ED for PA projection in digital chest radiography in some major hospitals is higher than National Diagnostic Reference Level (NDRL). Conclusion: Therefore optimization process should be considered seriously at national level to reduce patient exposure in digital chest radiography in Iran. Iran. J. Radiat. Res., 2012 10(3‐4): 139‐143
منابع مشابه
patient effective dose evaluation for chest x-ray examination in three digital radiography centers
background: the radiation doses resulting from diagnostic x-ray examinations are routinely measured in terms of entrance surface dose (esd) and effective dose (ed). in this study, for the purpose of radiation protection, the radiation doses received from digital chest x-ray examination were evaluated in terms of esd and ed. material and methods: the ed was calculated by using the mcnp monte car...
متن کاملEffective Dose Evaluation of Critical Organes in Digital Radiography Exames
Background and Aim: Due to the increasing number of radiographic tests, TLD dosimeters can be used to measure the effective dose of critical organs in various radiographic tests. In this research, the progression of analogue to digital radiology devices, which facilitates and accelerates the performance of radiographs, especially emergency patients, was investigated, and then the effective dose...
متن کاملPatient dose in routine X-ray examinations in Yazd state
Background: Medical x-rays are the largest man-made source of public exposure to ionizing radiation. It is important to avoid conditions where the amount of radiation used is more than that needed for the procedure. Materials and Methods: The Entrance Skin Exposure (ESE) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. The ESEs we...
متن کاملX-ray detectors for digital radiography.
Digital radiography offers the potential of improved image quality as well as providing opportunities for advances in medical image management, computer-aided diagnosis and teleradiology. Image quality is intimately linked to the precise and accurate acquisition of information from the x-ray beam transmitted by the patient, i.e. to the performance of the x-ray detector. Detectors for digital ra...
متن کاملPatient dose management in digital radiography
PURPOSE To present the experience in patient dose management and the development of an online audit tool for digital radiography. MATERIALS AND METHODS Several tools have been developed to extract the information contained in the DICOM header of digital images, collect radiographic parameters, calculate patient entrance doses and other related parameters, and audit image quality. RESULTS Th...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 10 شماره None
صفحات 139- 143
تاریخ انتشار 2012-12
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023