Patient dose values during interventional cardiology examinations in Yazd hospital, Iran

نویسندگان

چکیده مقاله:

Background: The number of interventional cardiology (IC) procedures has increased rapidly. coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. However, it is also known that these procedures are associated with high radiation doses due to long fluoroscopy time (T), and large number of cineradiography frames (F). These levels of radiation may even lead to radiation skin injuries under certain conditions. Materials and Methods: A detailed study of radiation doses received by 168 patients who underwent coronary angiography (CA), and 84 patients who underwent percutaneous transluminal coronary angioplasty (PTCA) using 3 angiography X-ray systems in two hospitals of Yazd-Iran is presented. An air kerma-area product (KAP) meter was used for patient dosimetry. KAP, fluoroscopy time and total number cine frames for CA and PTCA procedures were recorded for each patient. Results: Mean ± SD of KAP in CA and PTCA were 33 Gy.cm2 ± 18.8 Gy.cm2 and 80.3 Gy.cm2 ± 65.6 Gy.cm2 respectively. The comparison showed that CA KAP (33Gy.cm2), fluoroscopy time (2.7±2.4min), and cine frames number (571±149) except of on case, were lower than (P<0.001) the results of other studies and mean KAP due to PTCA procedures, except for three cases, were not significatly different from the other references’ results. Conclusion: The high level expert cardiologists couldn't have a significant effect on the decrease of patient dose since they should also teach angiography examinations to medicine students. With increasing patient BMI the value of KAP increased, but the fluoroscopy time and cineframes number did not change significantly. In addition, the results showed that the use of flat panel detector was not sufficient for decreasing patient dose, and system's adjustment was more important. Iran. J. Radiat. Res., 2009 6 (4): 167-172

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

patient dose values during interventional cardiology examinations in yazd hospital, iran

background: the number of interventional cardiology (ic) procedures has increased rapidly. coronary angiography (ca) and percutaneous transluminal coronary angioplasty (ptca) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. however, it is also known that these procedures are associated with high radiation doses due to long f...

متن کامل

Patient dose resulting from CT examinations in Yazd, Iran

Background: With the introduction of computed tomography in diagnostic radiology a new and fundamentally different imaging modality has become available. Meanwhile, it is clear that the absorbed doses by the patients during CT were relatively high in comparison with those of other diagnostic radiology techniques. The aim of this survey was to determine the average absorbed dose in Yazd provin...

متن کامل

Evaluation of Maximum Patient Skin Dose Arising from Interventional Cardiology Using Thermoluminescence Dosimeter in Mashhad, Iran

Introduction The increasing practice of interventional fluoroscopy in diagnosis and treatment of cardiovascular disease has risen attention to improve radiation protection of patients and cardiologists in these relatively high dose techniques. Therefore, nowadays there is an emphasis on the measurement of radiation dose received by patients and cardiologists arising from the relevant procedures...

متن کامل

Patient dose in routine X-ray examinations in Yazd state

Background: Medical x-rays are the largest man-made source of public exposure to ionizing radiation. It is important to avoid conditions where the amount of radiation used is more than that needed for the procedure. Materials and Methods: The Entrance Skin Exposure (ESE) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. The ESEs we...

متن کامل

patient dose resulting from ct examinations in yazd, iran

background: with the introduction of computed tomography in diagnostic radiology a new and fundamentally different imaging modality has become available. meanwhile, it is clear that the absorbed doses by the patients during ct were relatively high in comparison with those of other diagnostic radiology techniques. the aim of this survey was to determine the average absorbed dose in yazd province...

متن کامل

Assessment of Patient Dose from CT Examinations in Khorasan, Iran

Introduction Computed Tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. Ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. Yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. Materials and Methods Two refe...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 6  شماره None

صفحات  167- 172

تاریخ انتشار 2009-03

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023