Passive Energy Air-to-Water Heat Pipe Based Heat Exchanger and its Potential of Air Pre-cooling in Air Conditioning Systems for Iran Climate
نویسنده
چکیده مقاله:
Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To this end, effectiveness-NTU approach was employed to determine the thermal performance of the heat exchanger. Water-to-air HPHEX with different numbers of rows namely two, four, and six was studied to determine the heat transfer characteristics of the heat exchanger. The thermal performance of the water-to-air HPHEX was investigated under different operating conditions in terms of evaporator inlet air and condenser inlet water coil face velocities and temperatures. After determining the thermal performance of the water-to-air HPHEX, the air pre-cooling capability of the water-to-air HPHEX was explored hour-by-hour for the required months of the year by using TRNSYS software. Based on the simulations results, the water-to-air HPHEX shows an acceptable thermal performance under the operating conditions. In addition, studies showed that the water-to-air HPHEX has a significant capability for air pre-cooling, which makes it applicable to be implemented in the air-conditioning systems operating in south of Iran.
منابع مشابه
Fully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology
The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...
متن کاملHeat transfer enhancement due to air bubble injection into a horizontal double pipe heat exchanger
If an air flow is injected into a liquid fluid, many ambulant air bubbles are formed inside the fluid. Air bubbles move inside the liquid fluid because of the buoyancy force, and the mobility of these air bubbles makes sizable commixture and turbulence inside the fluid. This mechanism was employed to enhance the heat transfer rate of a horizontal double pipe heat exchanger in this paper. Howeve...
متن کاملEvaluation of Peak Shifting and Energy Saving Potential of Ice Storage Based Air Conditioning Systems in Iran
Thermal energy storage (TES) system has been introduced as a practical facility for shifting load from peak hours to off-peak hours. Because of different energy consumption during day and night, peak and off peak period is created on load curve. Ice storage technology which is a kind of TES system, is implemented in different points of the world with the purpose of solving load shifting problem...
متن کاملDiagnosis of Heat Exchanger Scales in Cooling Water Systems
An experimental database is compiled in order to fingerprint the scales formed over the hot surfaces of heat exchangers, in cooling water systems or other systems with similar chemistry. To collect these data, a dynamic simulating pilot plant was designed with considerable application flexibility among which simultaneous flow of water with different velocity and heat fluxes to three simulat...
متن کاملheat transfer enhancement due to air bubble injection into a horizontal double pipe heat exchanger
if an air flow is injected into a liquid fluid, many ambulant air bubbles are formed inside the fluid. air bubbles move inside the liquid fluid because of the buoyancy force, and the mobility of these air bubbles makes sizable commixture and turbulence inside the fluid. this mechanism was employed to enhance the heat transfer rate of a horizontal double pipe heat exchanger in this paper. howeve...
متن کاملEvaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners
There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید