OPTIMIZED TUNED LIQUID COLUMN DAMPERS FOR EARTHQUAKE OSCILLATIONS OF HIGH-RISE STRUCTURES INCLUDING SOIL EFFECTS

نویسندگان

  • A. Farshidianfar
  • S. Soheili
چکیده مقاله:

This paper investigates the optimized parameters for the tuned liquid column dampers to decrease the earthquake vibrations of high-rise buildings. Considering soil effects, the soilstructure interaction (SSI) is involved in this model. The Tuned Liquid Column Damper (TLCD) is also utilized on the roof of the building. Since the TLCD is a nonlinear device, the time domain analysis based on nonlinear Newmark method is employed to obtain the displacement, velocity and acceleration of different stories and TLCD. To illustrate the results, Kobe earthquake data is applied to the model. In order to obtain the best settings for TLCD, different parameters of TLCD are examined with constant mass quantity. The effective length, head loss coefficient, cross sectional ratio and length ratio of TLCD are assumed as the design variables. The objective is to reduce the maximum absolute and Root Mean Square (RMS) values of displacement and acceleration during earthquake vibration. The results show that the TLCDs are very effective and beneficial devices for decreasing the oscillations of high-rise buildings. It is indicated that the soil type highly affects the suitable parameters of TLCD subjected to the earthquake oscillations. This study helps the researchers to the better understanding of earthquake vibration of the structures including soil effects, and leads the designers to achieve the optimized TLCD for the high-rise buildings.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tuned Mass Dampers for Earthquake Vibrations of High-rise Buildings using Bee Colony Optimization Technique

This paper investigates the application of Artificial Bee Colony (ABC) method for the optimization of Tuned Mass Dampers (TMDs) employed for high-rise structures including Soil Structure Interaction (SSI). The model is a 40-story building, and Newmark method is utilized for the structure response to Bam earthquake data. The objective is to decrease both maximum displacement and accelerati...

متن کامل

OPTIMIZATION CRITERIA FOR DESIGN OF TUNED MASS DAMPERS INCLUDING SOIL–STRUCTURE INTERACTION EFFECT

Many researches have focused on the optimal design of tuned mass damper (TMD) system without the effect of soil–structure interaction (SSI), so that ignoring the effect of SSI may lead to an undesirable and unrealistic design of TMD. Furthermore, many optimization criteria have been proposed for the optinal design of the TMD system. Hence, the main aim of this study is to compare different opti...

متن کامل

earthquake vibration control of structures using tuned liquid dampers: experimental studies

earlier studies have shown conclusively that a tuned liquid damper (tld) is effective for controlling vibrations in structures subjected to narrow-banded wind excitations. a recent numerical study has shown that if the design parameters of a tld are properly set, this device could also be very effective for controlling structural vibration to broad-banded earthquake excitations. here the result...

متن کامل

Earthquake Analysis of Base Isolated Structures Including Soil-Structure Interaction

A frequency domain dynamic analysis is needed to obtain the response of structures constructed on a system of base isolators on flexible soil when subjected to earthquake ground motion. In such systems, the lateral stiffness of the base isolators is so small, compared to the structural stiffness, that in an earthquake attack the fundamental vibration mode dominates the response. With this in mi...

متن کامل

Earthquake Analysis of Base Isolated Structures Including Soil-Structure Interaction

A frequency domain dynamic analysis is needed to obtain the response of structures constructed on a system of base isolators on flexible soil when subjected to earthquake ground motion. In such systems, the lateral stiffness of the base isolators is so small, compared to the structural stiffness, that in an earthquake attack the fundamental vibration mode dominates the response. With this in mi...

متن کامل

OPTIMIZATION OF TMD PARAMETERS FOR EARTHQUAKE VIBRATIONS OF TALL BUILDINGS INCLUDING SOIL STRUCTURE INTERACTION

This paper investigates the optimized parameters of Tuned Mass Dampers (TMDs) for high-rise structures considering Soil Structure Interaction (SSI) effects. Three optimization methods, namely the ant colony optimization (ACO) technique together with artificial bee colony (ABC) and shuffled complex evolution (SCE) methods are utilized for the optimization of TMD Mass, damping coefficient and spr...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 2  شماره 2

صفحات  221- 234

تاریخ انتشار 2012-06

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023