Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system
نویسندگان
چکیده مقاله:
Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and non-pixelated parallel hole collimators and CZT detector on the functional parameters (including the spatial resolution and sensitivity) and the image quality of a HiRe- SPECT imaging system using SIMIND Monte Carlo program. Materials and Methods: In this study we simulated a HiRe-SPECT small animal imaging system with a pixelated CsI (Na) detector (1×1×5 mm3) and evaluated the system functional parameters and image quality. The collimator features were included; hole diameter of 1.2 mm, septal thickness of 0.2 mm, and hole length of 34 mm. We designed the pixelated collimator with rectangular hole shapes and compared with non-pixelated Hexagonal parallel hole collimator (LEHR) based on CZT detector. In pixelated collimator, hole size and pixel size were the same (1×1 mm2). Then the planar scans of a 99mTc point source and SPECT scans of a digital mini Jaszczak phantom and liver scans of a voxelized MOBY mouse phantom were simulated with SIMIND. Slices were reconstructed using the maximum-likelihood expectation maximization (MLEM) with four iterations, matrix size of 128 × 128 × 128 and voxel size of 0.3 mm. The framework of CASTOR (Version 1.0) was used for the MLEM algorithm. We assessed the spatial resolution, sensitivity and image contrast to conclude an optimized HiRe-SPECT system. Results: The results on simulations showed that the planar spatial resolution of the pixelated and LEHR parallel hole collimators was 2.4 and 3.6 mm in terms of full width at half maximum (FWHM), respectively. Also, the sensitivity of the LEHR and pixelated rectangular collimators calculated 34.04 and 15.15 Cps/MBq, respectively. To compensate the reduction sensitivity in pixelated collimator, the CZT semiconductor detector was used. The CZT detector improved the sensitivity about 1.7 times higher than this by the CsI (Na). The minimum detectable size of hot rods in mini Jaszczak phantom on the reconstructed images were determined in the sectors of 1.8 with the pixelated collimator, and 2.4 mm for the LEHR collimator at a 5 cm distance from the phantom. Image quality and contrast of the liver of MOBY phantom and hot rods in the mini Jaszczak phantom with pixelated collimator were obtained about 1.5 times better than the LEHR collimator. Conclusion: Based on our results, we recommend the rectangular pixelated parallel-hole collimator for a high-resolution with a CZT pixelated semiconductor detector for improving the sensitivity of HiRe-SPECT systems.
منابع مشابه
Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study
Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...
متن کاملevaluation of the performance of parallel-hole collimator for high resolution small animal spect: a monte carlo study
introduction: image quality and accuracy of in vivo activity quantification in spect are affected by collimator penetration and scatter components, especially in high energy imaging. these phenomena highly depend on the collimator characteristic and photon energy. the presence of penetrated and scattered photons from collimator in spect images degrades spatial resolution, contrast and image qua...
متن کاملAn Estimation Error Bound for Pixelated Sensing
This paper considers the ubiquitous problem of estimating the state (e.g., position) of an object based on a series of noisy measurements. The standard approach is to formulate this problem as one of measuring the state (or a function of the state) corrupted by additive Gaussian noise. This model assumes both (i) the sensor provides a measurement of the true target (or, alternatively, a separat...
متن کاملUnitary rotation and gyration of pixelated images on rectangular screens.
In the two space dimensions of screens in optical systems, rotations, gyrations, and fractional Fourier transformations form the Fourier subgroup of the symplectic group of linear canonical transformations: U(2)F⊂Sp(4,R). Here, we study the action of this Fourier group on pixelated images within generic rectangular Nx×Ny screens; its elements here compose properly and act unitarily, i.e., witho...
متن کاملDetailed Studies of Pixelated CZT Detectors Grown with the Modified Horizontal Bridgman Method
The detector material Cadmium Zinc Telluride (CZT) achieves excellent spatial resolution and good energy resolution over a broad energy range, several keV up to some MeV. Presently, there are two main methods to grow CZT crystals, the Modified High-Pressure Bridgman (MHB) and the High-Pressure Bridgman (HPB) process. The study presented in this paper is based on MHB CZT substrates from the comp...
متن کامل4D STEM: High efficiency phase contrast imaging using a fast pixelated detector
Phase contrast imaging is widely used for imaging beam sensitive and weak phase objects in electron microscopy. In this work we demonstrate the achievement of high efficient phase contrast imaging in STEM using the pnCCD, a fast direct electron pixelated detector, which records the diffraction patterns at every probe position with a speed of 1000 to 4000 frames per second, forming a 4D STEM dat...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 15 شماره Special Issue-12th. Iranian Congress of Medical Physics
صفحات 156- 156
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023