Optimization of a SPECT system for imaging of 90Y in liver using Monte Carlo method
نویسندگان
چکیده مقاله:
Introduction: Acquiring a high quality image has assigned an important concern for obtaining accurate diagnosis in nuclear medicine. Detector and collimator are critical component of Single Photon Emission Computed Tomography (SPECT) imaging system for giving accurate information from exact pattern of radionuclide distribution in the target organ. The images are strongly affected by the attenuation, scattering, and response of the detector and collimator. Method and material: The Planar and SPECT scans of a Y90 point source and also an extended Cardiac- Torso(XCAT) computerized phantom with the experiment and simulated systems were prepared. The SIMIND Monte Carlo program was used for simulating Siemen’s dual head variable angle SPECT imaging system with 4 detectors and 10 collimators. After verification and validation of the simulated system, the similar scans of the phantoms were compared from the point of view of image quality for 4 scintillator crystals including: NaI(Tl), BGO, LuAG: Ce, LaBr3 and also 10 collimators: Pb, Pb-Sb, Pb-Sb3, Pb-bi-Sn19, Pb-bi Sn375, Pb-bi-Sn50, Pb-bi-Sn-cd10, Pb-bi-Sn-cd125, Pt and Pt-Co. The parameters of energy and spatial resolution, and sensitivity of the systems were compared. Images were analyzed qualitatively by two nuclear medicine specialists. RESULTS: FWHM of the mentioned crystals and collimators obtained where: NaI (Pb, 0.3853) and BGO (Pb-Sb, 0.406), (Pb-Bi-Sn375, 0.405), (Pb-Bi-Sn-cd125, 0.375), and LuAG: Ce crystal (Pb-Sb, 0.425), (Pb- Bi-Sn19, 0.407), (Pb-Bi-Sn375, 0.417) and also LaBr3 (Pb-Bi-Sn375, 0.407), (Pb-Bi-Sn50, 0.430), (Pt-Co, 0.355). Medical diagnosis of the SPECT images of the phantom showed that the system with NaI(Tl)and LaBr3 by Pb-Sn3 collimator potentially provides a better detectability for hot lesions in the liver of XCAT phantom. CONCLUSIONS: The results showed that crystal NaI(Tl)and LaBr3 by Pb-Sn3 collimator has a high sensitivity and resolution, and also provides a better lesion detectability from the point of view of image quality on XCAT phantom.
منابع مشابه
Absorbed dose of Fetus in SPECT-CT Imaging of Mother's Abdomen Regions using Monte Carlo method
SPECT-CT is an imaging method for diagnosing diseases and studying physiology of the body. In this type of imaging, due to the use of radiopharmaceutical for imaging (SPECT) and X-rays (CT), a relatively high dose of radiation is introduced into the patient. If the patient is pregnant, considering that the developing fetus is sensitive to any radiation in the uterus throughout the entire period...
متن کاملBremsstrahlung imaging from the liver using the Monte Carlo simulation
Introduction: Most beta and gamma radiation radioisotopes used for treatment are not suitable for imaging. The bremsstrahlung images on a conventional gamma camera helped to localize the radionuclide within and outside of the lesion. Secondary scattering of gamma rays of higher energy and bremsstrahlung causes contamination in the energy window and reducing the contrast and resolution of the im...
متن کاملPlanar and SPECT Monte Carlo acceleration using a variance reduction technique in I131 imaging
Background: Various variance reduction techniques such as forced detection (FD) have been implemented in Monte Carlo (MC) simulation of nuclear medicine in an effort to decrease the simulation time while keeping accuracy. However most of these techniques still result in very long MC simulation times for being implemented into routine use. Materials and Methods: Convolution-based force...
متن کاملAttenuation Correction in SPECT during Image Reconstruction using an Inverse Monte Carlo Method: A Simulation Study
Introduction: The main goal of SPECT imaging is to determine activity distribution inside the organs of the body. However, due to photon attenuation, it is almost impossible to do a quantitative study. In this paper, we suggest a mathematical relationship between activity distribution and its corresponding projections using a transfer matrix. Monte Carlo simulation was used to find a precise tr...
متن کاملA Monte Carlo study of SPECT in boron neutron capture therapy for a heterogeneous human phantom
Background: Boron neutron capture therapy (BNCT) is a binary radiotherapy combining biochemical targeting with neutron irradiation. However, monitoring the boron distribution is a fundamental problem in BNCT. Prompt gamma rays emitted by boron capture reaction can be used to address the issue. Materials and Methods: The general-purpose Monte Carlo toolkits Geant4 and MCNP were used for the simu...
متن کاملMonte Carlo-based optimization of a gamma probe system for sentinel lymph node mapping
Introduction: Sentinel lymph node biopsy (SLNB) is a standard surgical technique to identify sentinel lymph node (SLN) for the staging of early breast cancer. Nowadays, two methods are used for the identification of SLN: blue dye method aiding visually and radioactive dye using gamma detector. A wide range of gamma probe systems with different design and performance are used in...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 15 شماره Special Issue-12th. Iranian Congress of Medical Physics
صفحات 262- 262
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023