Nutrient Elimination from Effluent of Municipal Wastewater Treatment Plant Applying Horizontal Roughing Filter

نویسندگان

  • Amin Bagheri Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
  • Amir Hossein Mahvi Department of Environmental Health Engineering, Tehran University of Medical Sciences, Tehran, Iran
  • Kamal Ghadiri Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
  • Mohammad Khazaei Research Center for Environmental Pollutants, Department of Environmental Health Engineering, Qom University of Medical Sciences, Qom,
  • Nader Yousefi School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
چکیده مقاله:

High levels of turbidity and suspended solids are the major disadvantages of aerated lagoons. Aerated lagoon effluent filtration was investigated by Horizontal Roughing Filter (HRF). Removal efficiencies were determined by examining total phosphorus (TP) and total Kjeldahl Nitrogen (TKN) from HRF influent and effluent, simultaneously. HRF pilot system located on effluent pump station of Qom wastewater treatment plant and was put into operation at the filtration rate of 1 m3/m2.h. The main objective was to evaluate the performance of horizontal roughing filter for nutrient removal from aerated lagoon effluent. The filter was fed with continuously aerated lagoon effluent during a 62 days filtration run period. TKN and TP removal efficiencies were 46.6% and 53.8%, respectively. The average inlet and outlet TKN during filtration were 14.49 ±1.63 and 7.73 ±2.84 mg NH3/L, respectively. Moreover, TP was measured 5.7 ±0.83 and 2.63 ±0.63 mg P/L for filter inlet and outlet, respectively. It was shown that horizontal roughing filter has a significant effect on total Kjeldahl nitrogen (p<0.001) and total phosphorus removal (p<0.005).

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

nutrient elimination from effluent of municipal wastewater treatment plant applying horizontal roughing filter

high levels of turbidity and suspended solids are the major disadvantages of aerated lagoons. aerated lagoon effluent filtration was investigated by horizontal roughing filter (hrf). removal efficiencies were determined by examining total phosphorus (tp) and total kjeldahl nitrogen (tkn) from hrf influent and effluent, simultaneously. hrf pilot system located on effluent pump station of qom was...

متن کامل

Efficiency of horizontal roughing filter in removing nitrate, phosphate and chemical oxygen demand from effluent of waste stabilization pond

Background: The effective size of the end grain of horizontal roughing filters (HRFs) is larger than 2 mm. This study aimed to examine the efficiency of HRFs in removing nitrate, phosphate, and chemical oxygen demand (COD) from effluent of a wastewater stabilization pond. Methods: This experimental study was conducted in 2013. The pilot project was transferred to the Karaj wastewater treatment ...

متن کامل

Efficiency of Horizontal Roughing Filter in Removing Suspended Solids from Effluent of Waste Stabilization Ponds in 2013

Background & Aims of the Study: The Horizontal roughing filters (HRF) are generally formed with three layers. The size of the course at the beginning of the flow path is large and at the end is small. This kind of layering increases absorption capacity while the solids entering the bed&ndash;depth gradually separate because of the decline in the holes&rsquo; diameters. This stu...

متن کامل

Pharmaceuticals in Wastewater Treatment Plant Effluent Waters

Pharmaceuticals are being used at an increasing rate, and end up in wastewater through excretion and disposal. They also end up in the effluent water of wastewater treatment plants because they are not specifically designed for pharmaceutical removal. Several studies suggest diverse negative effects on aquatic life that are exposed to these trace amounts of pharmaceuticals in their habitats. Th...

متن کامل

Fuzzy rule-based inference of reasons for high effluent quality in municipal wastewater treatment plant

−A fuzzy inference system (FIS), which could classify the state of effluent quality if it was high or not and identify visually the reasons for the high effluent quality in municipal wastewater treatment plants (WWTPs), was developed in this study. The decision tree algorithm and fuzzy technique were applied in the development of this system. By applying the classification and regression tree (...

متن کامل

Microplastic pollution is widely detected in US municipal wastewater treatment plant effluent.

Municipal wastewater effluent has been proposed as one pathway for microplastics to enter the aquatic environment. Here we present a broad study of municipal wastewater treatment plant effluent as a pathway for microplastic pollution to enter receiving waters. A total of 90 samples were analyzed from 17 different facilities across the United States. Averaging all facilities and sampling dates, ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 1  شماره 1

صفحات  1- 5

تاریخ انتشار 2016-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023