Noise Effects on Modal Parameters Extraction of Horizontal Tailplane by Singular Value Decomposition Method Based on Output Only Modal Analysis

نویسندگان

  • M.H Sadeghi Vibration and Modal Analysis Research Lab, Faculty of Mechanical Engineering, University of Tabriz, Tabriz, Iran
  • P Jalali Vibration and Modal Analysis Research Lab, Faculty of Mechanical Engineering, University of Tabriz, Tabriz, Iran
  • R Hassannejad Vibration and Modal Analysis Research Lab, Faculty of Mechanical Engineering, University of Tabriz, Tabriz, Iran
  • S Varahram Vibration and Modal Analysis Research Lab, Faculty of Mechanical Engineering, University of Tabriz, Tabriz, Iran
چکیده مقاله:

According to the great importance of safety in aerospace industries, identification of dynamic parameters of related equipment by experimental tests in operating conditions has been in focus. Due to the existence of noise sources in these conditions the probability of fault occurrence may increases. This study investigates the effects of noise in the process of modal parameters identification by Output only Modal Analysis (OMA) method using Singular Value Decomposition (SVD) algorithm. The study case is the horizontal tailplane of the aircraft; therefore, at first, the modal parameters of the tailplane are obtained numerically. Then a cantilever beam is used to perform experimental tests with regard to the high aspect ratio of the modeled tailplane. The modal parameters of the beam are obtained nonparametrically by Experimental Modal Analysis (EMA) and OMA. In order to investigate the effects of noise in a controlled manner, the artificial excitation namely the shaker with the random force is used. Then, the effects of noisy measurements on the specifications of the system in EMA and OMA methods are investigated. The results indicate that: 1. The OMA method has more resistance against the noise for extracting natural frequencies. 2. The results of the Modal Assurance Criterion (MAC) values by EMA method, in the condition of noise existence in output data, are worse than the noise existence in input data. 3. The average of MAC values in general condition of EMA method by noisy input & output data is worse than the OMA method.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Output-only Modal Analysis of a Beam Via Frequency Domain Decomposition Method Using Noisy Data

The output data from a structure is the building block for output-only modal analysis. The structure response in the output data, however, is usually contaminated with noise. Naturally, the success of output-only methods in determining the modal parameters of a structure depends on noise level. In this paper, the possibility and accuracy of identifying the modal parameters of a simply supported...

متن کامل

Reference-based Stochastic Subspace Identification for Output-only Modal Analysis

When performing vibration tests on civil engineering structures, it is often unpractical and expensive to use arti"cial excitation (shakers, drop weights). Ambient excitation on the contrary is freely available (tra$c, wind), but it causes other challenges. The ambient input remains unknown and the system identi"cation algorithms have to deal with output-only measurements. For instance, realisa...

متن کامل

Using Singular Value Decomposition to Compare Correlated Modal Vectors

A tool is needed to track several mode shape estimates from iterative or repeated (variability) testing. Modal Assurance Criterion (MAC) is a well known modal vector comparison tool, however it can compare only two modal vectors at a time. A method to compare multiple samples of modal vector is presented The approach begins with mode shape correlation and correspondence. Pseudo orthogonality is...

متن کامل

Modal parameters identification of power transformer winding based on improved Empirical Mode Decomposition method

Modal parameters of power transformer winding are closely related to transformer manufacturing and detection technology of winding deformation based on vibration analysis method. Aimed at identifying the modal parameters of transformer winding accurately, a modal experiment is designed and made on a real 10 kV power transformer. An improved Empirical Mode Decomposition (EMD) algorithm is propos...

متن کامل

investigation of effective parameters on the rigidity of light composite diaphragms (psscb) by fem

در این رساله با معرفی سقف های psscb متشکل از ترکیب ورق های فولادی ذوزنقه ای و تخته های سیمانی الیافی به عنوان سقف های پیش ساخته (سازگار با سیستم سازه ای قاب های فولادی سبک) به بررسی پارامترهای موثر بر صلبیت سقف، پرداخته می شود. در تحقیق حاضر ابتدا به مدل سازی دو نمونه سقف آزمایش شده، به روش اجزاء محدود با استفاده از نرم افزار تحلیلی abaqus ver 6.10 پرداخته شده است. نمونه های ساخته شده تحت اعما...

Output-Only Modal Identification of a Nonuniform Beam by using Decomposition Methods

Reduced-order mass weighted proper orthogonal decomposition (RMPOD), smooth orthogonal decomposition (SOD), and state variable modal decomposition (SVMD) are used to extract modal parameters from a nonuniform experimental beam. The beam was sensed by accelerometers. Accelerometer signals were integrated and passed through a high-pass filter to obtain velocities and displacements, all of which w...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 11  شماره 3

صفحات  678- 689

تاریخ انتشار 2019-09-30

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023