New Metal Shield for the Endotracheal Tube during Laser Endolaryngeal Surgery

نویسندگان

  • Mohammad-Vaheed El-Anwar Department of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine, Zagazig University, Zagazig, Egypt.
  • Nasser-Naghib Mohamed Department of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine, Zagazig University, Zagazig, Egypt.
چکیده مقاله:

Introduction: To present and assess a newly designed autoclavable, reusable tube shield for an endotracheal tube (ETT) during laser laryngeal surgery.   Materials and Methods: This study included patients scheduled for endolaryngeal laser surgery. A carbonated stainless-steel hemisphere shield (~1.5×0.6 mm) connected to a silk thread passing through a hole in its middle near upper edge was used. Under general anesthesia, patients were intubated orally using a small cuffed polyvinyl ETT, filling the cuff with saline. When the laser was used, the shield was applied either to the side of the tube or anterior to it, depending on the site of the laser procedure. The shield could easily be repositioned when needed during surgery.   Results: In 25 cases (six cordectomy for glottic carcinomas and 19 posterior cordotomy for bilateral vocal cord paralysis), application of the shield over the ETT was easy and the shield could be easily and simply fitted in all cases, with change in position achieved easily during the work as required. The shield over the ETT could not be penetrated by the laser, regardless of the gas composition or laser energy. No intraoperative complications were encountered in any of our cases. Recovery was event-free in all patients without the need for admission to an intensive care unit.   Conclusion: The newly designed autoclavable reusable stainless-steel shield designed for an ETT could be safely, easily, and effectively used during laser laryngeal surgery with low cost and easy availability. However, comparative and multicenter studies are still needed.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endotracheal tube ignition during CO2 laser surgery of the larynx.

We report a case of endotracheal tube fire occurring during CO2 laser surgery of the larynx. The ignition of an endotracheal tube was thought to be caused by laser penetration of an unprotected portion of the tube during resection of vocal cord tumour. Fire hazard is inevitable when a laser is used in the path of combustible gases and in the presence of flammable objects. We discuss the methods...

متن کامل

Endotracheal tube fire during tracheostomy

Corresponding author: Eunju Lee, M.D., Department of Anesthesiology and Pain Medicine, Korea Cancer Center Hospital, 75, Nowon-gil (215-4 Gongneung-dong), Nowon-gu, Seoul 139-706, Korea. Tel: 82-2-970-2820, Fax: 82-2-970-2413, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http:// creativecommons...

متن کامل

The LMACTrach, a new approach for endotracheal intubation: Apilot study in 100 patients undergoing elective surgery

AbstractBackgroundand endotracheal intubation under direct vision in both anticipated and unexpecteddifficult intubation situations.: The LMA CTrach system is a new device for airway managementMethodsdifferent types of elective surgeries. After randomly selecting the patients for intubationwith this new device, the airway characteristics, height, weight, dental overbiteand thyromental distance ...

متن کامل

Endotracheal tube extubation force: adhesive tape versus endotracheal tube holder.

BACKGROUND Adhesive tape is commonly used to secure the endotracheal tube (ETT) in anesthesia and intensive-care settings. OBJECTIVE To determine the force required to extubate when the ETT is secured with adhesive tape or commercially available ETT holders. METHODS We orally intubated a simulation manikin with a standard 8.0-mm inner-diameter ETT, inflated the cuff to 20 cm H(2)O, and mea...

متن کامل

Comparison of the cuff pressure of a TaperGuard endotracheal tube and a cylindrical endotracheal tube after lateral rotation of head during middle ear surgery

BACKGROUND Positional change affects the cuff pressure of an endotracheal tube (ETT) in treacheally intubated patients. We compared the cuff pressure of a TaperGuard ETT and a cylindrical ETT after lateral rotation of head during middle ear surgery. METHODS Fifty-two patients aged 18-70 years underwent a tympanomastoidectomy under general anesthesia were randomly allocated to receive endotrac...

متن کامل

Changes in endotracheal tube cuff pressure during laparoscopic surgery in head-up or head-down position

BACKGROUND The abdominal insufflation and surgical positioning in the laparoscopic surgery have been reported to result in an increase of airway pressure. However, associated effects on changes of endotracheal tube cuff pressure are not well established. METHODS 70 patients undergoing elective laparoscopic colorectal tumor resection (head-down position, n = 38) and laparoscopic cholecystecomy...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 30  شماره 5

صفحات  291- 295

تاریخ انتشار 2018-09-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023