Monte Carlo Modeling of Dual and Triple Photon Energy Absorptiometry Technique

نویسندگان

  • Alireza Kamali-Asl Assistant Professor, Radiation Medicine Dept., Shahid-Beheshti University, Tehran, Iran
  • Arash Darafsheh M.Sc. in Radiation Medicine, Shahid-Beheshti University, Tehran, Iran
  • Seyed Mahmoudreza Aghamiri Associate Professor, Radiation Medicine Dept., Shahid-Beheshti University, Tehran, Iran
چکیده مقاله:

Introduction: Osteoporosis is a bone disease in which there is a reduction in the amount of bone mineral content leading to an increase in the risk of bone fractures. The affected individuals not only have to go through lots of pain and suffering but this disease also results in high economic costs to the society due to a large number of fractures.  A timely and accurate diagnosis of this disease makes it possible to start a treatment and thus preventing bone fractures as a result of osteoporosis. Radiographic methods are particularly well suited for in vivo determination of bone mineral density (BMD) due to the relatively high x-ray absorption properties of bone mineral compared to other tissues. Materials and Methods: Monte Carlo simulation has been conducted to explore the possibilities of triple photon energy absorptiometry (TPA) in the measurement of bone mineral content. The purpose of this technique is to correctly measure the bone mineral density in the presence of fatty and soft tissues. The same simulations have been done for a dual photon energy absorptiometry (DPA) system and an extended DPA system. Results: Using DPA with three components improves the accuracy of the obtained result while the simulation results show that TPA system is not accurate enough to be considered as an adequate method for the measurement of bone mineral density. Discussion: The reason for the improvement in the accuracy is the consideration of fatty tissue in TPA method while having attenuation coefficient as a function of energy makes TPA an inadequate method. Conclusion: Using TPA method is not a perfect solution to overcome the problem of non uniformity in the distribution of fatty tissue. 

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

monte carlo modeling of dual and triple photon energy absorptiometry technique

introduction: osteoporosis is a bone disease in which there is a reduction in the amount of bone mineral content leading to an increase in the risk of bone fractures. the affected individuals not only have to go through lots of pain and suffering but this disease also results in high economic costs to the society due to a large number of fractures.  a timely and accurate diagnosis of this disea...

متن کامل

Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus

The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...

متن کامل

The utility of single-photon absorptiometry and dual-energy x-ray absorptiometry.

T w o decades ago researchers at the University of Wisconsin showed that 125I photon absorptiometry could be used to measure bone mineral in the forearm easily and accurately with little radiation exposure (1). Surrounding the arm with water or other soft tissue-equivalent material of constant thickness provided uniform extra-skeletal attenuation; the incremental attenuation by bones was linear...

متن کامل

Determination of the Energy Windows for the Triple Energy Window Scatter Correction Method in Gadolinium-159 Single Photon Emission Computed Tomography Using Monte Carlo Simulation

Introduction: In radionuclide imaging, object scatter is one of the major factors leading to image quality degradation. Therefore, the correction of scattered photons might have a great impact on improving the image quality. Regarding this, the present study aimed to determine the main and sub-energy windows for triple energy window (TEW) scatter correction method usin...

متن کامل

Dual-energy x-ray absorptiometry of the forearm: reproducibility and correlation with single-photon absorptiometry.

Although single-photon absorptiometry (SPA) has been the predominant tool used to assess bone mineral density (BMD) in the forearm, the development of dual-energy x-ray absorptiometry (DEXA) provides the benefits of greater source stability, reduced scanning time, and improved image resolution compared to SPA. In the present study we used the DEXA bone densitometer (Hologic, Inc., Waltham, MA) ...

متن کامل

comparison of bone mineral density measured by dual x-ray, axial dual-energy photon x-ray absorptiometry and laser absorptiometry of calcaneus

the objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual x-ray and laser (dxl) in a cross-sectional study carried out in an osteoporosis clinic. measurements of bone mineral density (bmd) at proximal femur and spine were obtained by dual-energy photon x-ray absorptiometry (dexa). osteoporosis was defined by a dexa t-score <-2.5 at the femora...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 4  شماره Issue 3,4

صفحات  65- 73

تاریخ انتشار 2007-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023