چکیده مقاله:

Demand for high-performance cooling systems is one of the most challenging and virtual issues in the industry and Pulsating heat pipes are effective solutions for this concern. In the present study, the best predictor correlations of flow boiling and condensation are taken into account to model a single turn pulsating heat pipe mathematically. These considerations, result in derivation of more accurate results. The nucleate boiling phenomenon has been considered as the dominant mechanism of the boiling process in the evaporator. However, due to the annular flow assumption, a thin film of liquid is considered in calculation of the mass transfer out of the vapor plugs. All the fundamental relations such as momentum, mass and energy equations are solved implicitly, except the energy equation of liquid slug. The liquid slug displacement results are compared with the previous studies and the comparison indicates increase in both the frequency and the amplitude of the slug displacement. Moreover, the calculated heat flux is verified with the empirical results. The comparison shows an acceptable agreement between the findings, which is better than previous modelings without boiling and condensation. Furthermore, the effect of pipe diameter on the flow and heat transfer mechanisms has been derived. According to the results, by increasing the pipe diameter, despite a frequency decrease, the oscillation amplitude of liquid slug and total heat flux transferred into the pulsating heat pipe increases. Sensible heat contribution in the heat trasnfer mechanism reduces by higher pipe diameter values.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Investigation of Boiling and Condensation Heat Transfer of a two Phase Closed Thermosyphon

In this paper the heat transfer characteristics of a two-phase closed thermosyphon over a wide range of heat transfer rates, system pressure, aspect ratios and filling ratios were studied. The experiments focused on the boiling and condensation heat transfer characteristics of the thermosyphon. The experimental boiling and condensation heat transfer coefficients inside the thermosyphon were com...

متن کامل

Experimental Investigation of Boiling and Condensation Heat Transfer of a Two Phase Closed Thermosyphon

In this paper the heat transfer characteristics of a two-phase closed thermosyphon over a wide range of heat transfer rates, system pressure, aspect ratios and filling ratios were studied. The experiments focused on the boiling and condensation heat transfer characteristics of a thermosyphon with a copper tube having 25 and 32 mm inside and outside diameters. Distilled water was used as the wor...

متن کامل

Flow regime-based modeling of heat transfer and pressure drop in microchannel flow boiling

Local heat transfer coefficients and pressure drops during boiling of the dielectric liquid fluorinert FC-77 in parallel microchannels were experimentally investigated in recent work by the authors. Detailed visualizations of the corresponding two-phase flow regimes were performed as a function of a wide range of operational and geometric parameters. A new transition criterion was developed for...

متن کامل

Numerical analysis of heat transfer in pulsating turbulent flow in a pipe

Convection heat transfer in pulsating turbulent flow with large velocity oscillating amplitudes in a pipe at constant wall temperature is numerically studied. A low-Reynolds-number (LRN) k–e turbulent model is used in the turbulence modeling. The model analysis indicates that Womersley number is a very important parameter in the study of pulsating flow and heat transfer. Flow and heat transfer ...

متن کامل

Analysis of the nonlinear axial vibrations of a cantilevered pipe conveying pulsating two-phase flow

The parametric resonance of the axial vibrations of a cantilever pipe conveying harmonically perturbed two-phase flow is investigated using the method of multiple scale perturbation. The nonlinear coupled and uncoupled planar dynamics of the pipe are examined for a scenario when the axial vibration is parametrically excited by the pulsating frequencies of the two phases conveyed by the pipe. Aw...

متن کامل

The Effect of Linear Change of Tube Diameter on Subcooled Flow Boiling and Critical Heat Flux

One of the major industry problems is the flow boiling, where reaching to the critical heat flux (CHF) condition can lead to a temperature jump and damage of the systems. In the present study, the effects of a uniform change in tube diameter on subcooled flow boiling and CHF was numerically investigated. The Euler-Euler model was used to investigate the relationship between the two liquid and v...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 32  شماره 4

صفحات  569- 579

تاریخ انتشار 2019-04-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023