Microwave assisted digestion coupled with inductively coupled plasma optical emission spectrometry for determining element concentrations in halophytes

نویسندگان

  • Farokh Ghafarizadeh
  • Masoud Torabpour
  • Narges Chamkouri
چکیده مقاله:

Introduction: This study was carried out to determine elements (Li, Na, K, Mg, Ca, Ba, B, Al, Si, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Ag and P) in the Suaeda vermiculata (S. vermiculata) and Suaeda aegyptiaca (S. aegyptiaca) in three different regions of Southern Iran using inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion. Materials and methods: The present study was carried out the common halophytes, S. vermiculata and S. aegyptiaca in three different region of Dashti in Busher province, Iran, in early summer, 2013. S. vermiculata and S. aegyptiaca are native to the south, southern- east and Persian Gulf coastal and are recognized as Tahma and Kakol in Bushehr province. After drying at 95°C for 1 h to a constant weight, the samples were separated and weighed individually. The dried samples were homogenized and grounded using a mortar. Results: A new, simple and highly sensitive method was proposed for determination some elements in halophytes by ICP-OES. The limit of detection (LOD) was below 10 ngkg−1,and the relative standard deviations (RSD) were below 5%.The recoveries of all the elements were in the range of 88% to 108%, and the linear correlation coefficients (R) were 0.99. Conclusion: Advantages of this method were low limit of detection (LOD), the relative standard deviations (RSD), recoveries of all the vitamins were in the range of 88% - 108%, and the linear correlation coefficients (R) 0.99. Finally to the best of our knowledge there are no published research studies about determination of some element concentrations in halophytes and the proposed ICP-OES method has been successfully applied for determining element concentrations in halophytes.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

microwave assisted digestion coupled with inductively coupled plasma optical emission spectrometry for determining element concentrations in halophytes

introduction: this study was carried out to determine elements (li, na, k, mg, ca, ba, b, al, si, v, cr, mn, fe, co, ni, cu, zn, se, ag and p) in the suaeda vermiculata (s. vermiculata) and suaeda aegyptiaca (s. aegyptiaca) in three different regions of southern iran using inductively coupled plasma optical emission spectrometry (icp-oes) after microwave-assisted acid digestion. materials and m...

متن کامل

Inductively Coupled Plasma - Optical Emission Spectrometry

ACKNOWLEDGEMENTS INTRODUCTION CONTENTS 1.1 Forensic Science Investigations 1.2 Forensic Science Analysis 2 1.3 Inductively Coupled Plasma-Optical Emission Spectrometry 7 1.4 The Aims of This Investigation 8 2 INDUCTIVELY COUPLED PLASMA-OPTICAL EMISSION SPECTROMETRY 10 2 .l Introduction 2.2 The Inductively Coupled Plasma 2.3 Instrumentation Used in This Study 2.3.1 Radio Frequency Generator 2.3....

متن کامل

Marine Sediment Analysis Using Inductively Coupled Plasma Optical Emission Spectrometry

Inductively coupled plasma optical emission spectrometry was applied to the determination of trace impurities in tantalum powder. The matrix effects of tantalum in the determination of trace level impurities such as Cr, Fe, Nb, Ni, and Ti were studied by measuring the intensities of each trace element in solution at various concentrations of tantalum. As the concentration of the interfering ele...

متن کامل

Iodine determination in food by inductively coupled plasma mass spectrometry after digestion by microwave-induced combustion.

Iodine determination in food samples was performed by inductively coupled plasma mass spectrometry (ICP-MS) after digestion by microwave-induced combustion (MIC). Sample masses up to 500 mg of bovine liver, corn starch, milk powder, or wheat flour were completely combusted using the MIC system. Ammonium nitrate (6 mol l(-1) solution, 50 μl) was used as an aid for ignition and vessels were charg...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 2  شماره 1

صفحات  49- 56

تاریخ انتشار 2015-03

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023