Background: Cone-beam computed tomography (CBCT) scanners for image-guided radiotherapy are in clinical use today, but there has been no consensus on uniform acceptance to verify the CBCT image quality yet. The present work proposed new methods to fully evaluate the performance of CBCT in its three-dimensional (3D) reconstruction space. Materials and Methods: Compared to the traditional methods with only two-dimensional axial slice evaluated, the new methods were designed to evaluate the CBCT image quality not only in the axial slices but also along three dimensions and three sections. Image parameters were evaluated by scanning the corresponding phantom. Results: The new methods demonstrated the high spatial resolution, the image uniformity, the high CT numbers linearity, geometric accuracy and relatively poor performance in low contrast resolution, compared to the results of plan CT. Additionally, the spatial resolution, the CT number linearity and the image uniformity proved to be more superior along the z direction and in the cross-section. Furthermore, the spatial resolution and the CT value linearity decreased gradually when deviating from the center of rotation axis and accelerates the reduction towards the periphery area, suggesting that locating the target within the range of 4 cm around the isocenter during radiotherapy ensure the optimal spatial resolution and the CT value linearity. Conclusion: Results indicate that the proposed three-dimensional image quality evaluation holds the potential to complement existing standards to provide sufficient information for the CBCT image performance and thereby guiding the clinical applications of CBCT.
منابع مشابه
Three Dimensional Cone-beam Reconstruction of Micro Computed Tomography in the Breast Specimen
Traditionally, the specimen obtained from a breast biopsy can only be examined by a microscope. Although the resolution of microscope is high, it can only examine one thin section at a time. Hence, the microcalcifications next to the observed section may be missed. To solve for this problem, we acquire the specimen by a 3D micro computed tomography (microCT) with electron bombarded charged coup...
متن کاملQuality Assurance (QA) for Kilovoltage Cone Beam Computed Tomography (CBCT)
Precise targeting of the tumor is very important and imaging can be immensely helpful in this process. Hence the quality assurance of the imaging systems used to guide the beam is also essential. One could argue that it is as critical as quality assurance for the radiation dose output, since the right amount of radiation dose delivered to the wrong location can be as detrimental as delivering t...
متن کاملthree-dimensional assessment of the nasopalatine canal and the surrounding bone using cone-beam computed tomography
background and aims. because of increasing concerns about surgeries in the anterior maxilla, including implant placement, it is necessary to examine the morphology of the nasopalatine canal and its surrounding bones. this study aimed to analyze the shape and position of the nasopalatine canal and incisive foramen using cone-beam computed tomography (cbct). materials and methods. cbct images of ...
متن کاملThree Dimensional Study of Upper Airway in Different Antero-posterior Jaw Relationships through Cone Beam Computed Tomography
Introduction: This study aims at examining the difference of pharyngeal airways in patients with different occlusion postures, hoping to improve diagnostic methods and provide a stable treatment plan for orthodontic patients. Materials and Methods: The data were ga-thered through CBCT radiographies of patients from a specialized center for radiology. In each occlusion group according to the p...
متن کاملCorrelation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)
Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...
متن کاملAnatomic variations of sphenoid sinus from Cone Beam Computed Tomography images in the Iranian population
Aims: Sphenoid sinus is one of the most inaccessible paranasal sinus, and is closely correlated to many vascular and neural structures. Anatomic variation of the sphenoid sinus can complicate surgery in this area. The aim of the present investigation was to define the sphenoid sinus variations and the relevant structures using cone-beam computed tomography (CBCT). Methods: This cross-sectiona...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید