Measurement of Strontium-90 in the Persian Gulf Fish by Extraction Chromatography with Sr-resin and Liquid Scintillation Counter

نویسندگان

  • Anaraki Ardakani , Hossein Group of Chemistry, Department of Chemical Engineering, Islamic Azad University, Mahshahr Branch, Mahshahr, Iran
  • Firouzabadi , Maryam Group of Chemistry, Department of Chemical Engineering, Islamic Azad University, Mahshahr Branch, Mahshahr, Iran
  • Jalali Jahromi , Hossein Group of Chemistry, Department of Chemical Engineering, Islamic Azad University, Mahshahr Branch, Mahshahr, Iran
چکیده مقاله:

Background: Despite its beneficial effects on human life, the nuclear industry has its own risks. Strontium 90 (90Sr) is one of the most dangerous radionuclides produced by the uranium 235 fission, and replaces the bone calcium in the human body, which causes cancer. Ensuring the safety of nuclear facilities to protect employees, people and the environment is among the main goals of nuclear safety. Given close proximity of the Bushehr nuclear power plant to the Persian Gulf and the likelihood of 90Sr leaking into the marine ecosystem, this study aimed to measure this radionuclide in a sample of the bar-tail flathead fish (Platycephalus indicus) found in the Persian Gulf coastline, as people’s main source of food in the region. Materials and Methods: Samples were taken from 10 points around the Persian Gulf coastline. The samples were analyzed using chromatographic extraction by Sr-resin and counted by the Liquid Scintillation Counter.  Results: The concentration of strontium 90 measured in the fish samples was 0.252- 0.955 Bq.kg-1. The mean chemical efficiency in this method was 97.34 ± 0.97 percent. Conclusion: The amount of strontium 90 found in these samples was negligible and within the least detectable range. Despite the 10-year activity of Bushehr nuclear power plant, no evidence of contamination with strontium 90 was found. These results will be very useful in assessing the underlying contamination in environmental monitoring programs.  

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of chemical and radiochemical purity of [14C] clozapine by high performance liquid chromatography and liquid scintillation [Persian]

Introduction: The mechanism of action and metabolism of clozapine, a complex drug used in psychopharmacology, is not completely understood. The effects of this compound in human body are related to some interactions with serotonin and dopamine neurotransmitter receptors. To further elucidate the mechanism of action and to support ongoing drug metabolism studies, [14C] clozapine with suita...

متن کامل

the relationship of wtc with communication apprehension and self-perceived communication competene in english and persian context

بیشتر تحقیقات پیشین در زمینه تمایل به برقراری ارتباط به رابطه آن با عوامل فردی چون سن، جنس، نوع شخصیت و... صورت گرفته است. در صورتی که مطالعات کمتری به بررسی رابطه تمایل به برقراری ارتباط زبان آموزان فارسی زبان با ترس از برقراری ارتباط و توانش خود ادراکانه آنها در برقراری ارتباط در محیط فارسی و انگلیسی انجام شده است. بر اساس نظریه الیس (2008) تمایل به برقراری ارتباط جایگاه مهمی در زمینه آموزش م...

15 صفحه اول

determination of chemical and radiochemical purity of [14c] clozapine by high performance liquid chromatography and liquid scintillation [persian]

introduction: the mechanism of action and metabolism of clozapine, a complex drug used in psychopharmacology, is not completely understood. the effects of this compound in human body are related to some interactions with serotonin and dopamine neurotransmitter receptors. to further elucidate the mechanism of action and to support ongoing drug metabolism studies, [14c] clozapine with suitable ra...

متن کامل

Measurements of Strontium-90 in portuguese milk samples using liquid scintillation counting technique

The objective of this study is the implementation of a method combining extraction chromatography and liquid scintillation counting (LSC) technique to the determination of 90Sr in milk samples. The strontium separation is performed using the commercially available Sr-resin (Eichrom) and the beta counting is carried out using a liquid scintillation detector system (Tri-Carb 3170 TR/SL, Packard)....

متن کامل

Iron absorption. Measurement of ingested iron59 by a human whole-body liquid scintillation counter.

The availability of radioactive isotopes of iron led to the development of reliable methods of studying iron kinetics (1), but the absorption of iron by the gastrointestinal tract was still determined indirectly by the amount of unabsorbed iron excreted in the stools or by quantification of isotopic iron incorporated into hemoglobin (2-7). The availability of a whole-body counter in a clinical ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 23  شماره 6

صفحات  541- 553

تاریخ انتشار 2020-12

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023