Measurement Of Scatter Factors For Small Photon Fields Using Gaf chromic EBT2 Film
نویسندگان
چکیده مقاله:
Introduction: Small field dosimetry is challenging for radiotherapy dosimetry. measurement of the output factor in the air and water (Sc, Scp) is one of the input parameters for commissioning of treatment planning systems and beam modeling. The aims of this study are to measured Sc,Scp for small fields with EBT2 and Ion chamber and design a appropriate mini-phantom for small fields dosimetry with EBT2 film. Materials and Methods: output factors in air and water were measured for Siemens linear accelerator 6Mv energy and fields sizes (1-20cm) which irradiated by 200MU. Measurements were performed using a gafchromicfilm EBT2 and 0.6cc Farmer ion chamber and then the results were compared with Report of AAPM Group74 and TG155. For lateral electron equilibrium and electron contamination removal, two top of the water and Cerrobend were designed for film dosimetry and plexiglass buildup cap for Farmer chamber was applied. Results: It was observed that In-air output factors increased with field size, and this increase in Cerrobend top is less than water top and Farmer dosimeter.Sc measured in small field is good agreement with data TG74 (0.5%), also Scp result were compared with data TG155(4.1%), and the response of the film to the Ion chamber isalso in good agreement showed (2.4%). Conclusion: EBT2 film in measured output factors in air and wayer for small field as a good alternative to ion chamber dosimeters known as a standard dosimeter.
منابع مشابه
Small photon field dosimetry using EBT2 Gafchromic film and Monte Carlo simulation
Background: Small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (IMRT) and stereotactic radiosurgery (SRS) treatments. Accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. Hence the EBT2 (external beam therapy) Gafchromic film was used for dosimetry of sm...
متن کاملsmall photon field dosimetry using ebt2 gafchromic film and monte carlo simulation
background: small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (imrt) and stereotactic radiosurgery (srs) treatments. accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. hence the ebt2 (external beam therapy) gafchromic film was used for dosimetry of sm...
متن کاملDosimetric Evaluation of Linac Photon Small Fields using MAGIC Polymer Gels
Introduction: In radiotherapy, methods of treatment planning are becoming increasingly more complicated. This requires verification of the doses delivered to increasingly smaller and more precise regions. Radiotherapy techniques are continuously employing smaller and smaller field sizes to deliver tighter radiation doses with higher therapeutic ratios, generating interest among researchers to p...
متن کاملDose Distribution Evaluation and Independent Quality Check of Spherical INTRABEAM™ Applicators via Radiochromic EBT2 Film Measurement
Introduction: The present study was conducted to implement a simple practical independent quality check of depth dose and isotropy of the Intrabeam™ therapeutic X-ray machine using radiochromic EBT2 film. Material and Methods: Theindependent quality check of 1.5, 3.5, and 5-cm spherical Intrabeam™ applicators was accomplished using particular EBT2 film cutting pieces with internal rounded edge...
متن کاملDosimetric comparison between XR-RV3 and EBT2 radiochromic film in megavoltage photon beams
Background: Radiochromic film is used for radiation dose measurement, XR-RV3 is used in fluoroscopy and EBT2 film in radiation therapy. The aim was to determine if the dosimetric properties of these two films are comparable in megavolt photon beams. Materials and Methods: Comparison measurements included: calibration curves, heterogeneous phantom dose profiles, and nasopharynx dose distributio...
متن کاملMeasurement and comparison of head scatter factor for 9MV photon beam using the build-up cap and a columnar mini-phantom
Introduction: The Sc is an important parameter to monitor unit (MU) calculation in radiation therapy procedure. The aim of this study is to measurement and comparison of head scatter factor (Sc) for 9MV photon beam using the build-up cap and a columnar mini-phantom. Materials and Methods: The measurements performed using a calibrated ion chamber (Scanditron...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 15 شماره Special Issue-12th. Iranian Congress of Medical Physics
صفحات 374- 374
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023