Mean Activity Coefficients Measurements and Thermodynamic Modeling of the Ternary Mixed Electrolyte KCl + Lactose + Water System at T = 298.15 K
نویسندگان
چکیده مقاله:
In this work, the mean activity coefficients of KCl in the KCl+lactose +water system were determined using the potentiometric method. The electromotive force measurements were carried out on the galvanic cell without liquid junction of the type: Ag|AgCl|KCl (m), lactose (wt.%), H2O (1−wt.) %|K-ISE, in various mixed solvent systems containing 0, 5,7.5, 10 and 12.5 % mass fractions of lactose. The ionic strengths range was from 0.0003 to 2.000 kg.mol−1. The modeling of this ternary system was made based on the Pitzer ion-interaction model. The mean activity coefficients were correlated with Pitzer model and the adjustable Pitzer parameters (βo, β1 and Cø) were determined for the series under investigated system. Then, these parameters were used to calculate the amounts of thermodynamic properties such as osmotic coefficients and excess Gibbs free energies for under investigated systems. The results clearly indicated that a good correlation was obtained with the Pitzer model to describe this system.
منابع مشابه
Thermodynamic Study of the Ternary Electrolyte (1-Butyl-3-methylimidazolium chloride + sodium chloride + Water) System Using Potentiometric Measurements
In this paper, the thermodynamic properties of the aqueous mixed electrolyte system containing 1-butyl-3-methylimidazolium chloride ([BMIm]Cl) and NaCl are reported based on the potentiometric method. The potentiometric measurements were performed on the galvanic cells without liquid junction of the type:Ag-AgCl [BMIm]Cl (m1), NaCl(m2), H2O│IL-...
متن کاملConstruction of Cu2+-selective electrode and thermodynamic study of the ternary aqueous mixed electrolyte system (CuCl2, KCl, H2O) using nanocomposite-based potentiometric sensor
A nanocomposite membrane Cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (ETMOC) as a neutral ionophore. The electrode works properly. It responds to Cu2+ ion with a sensitivity of 29.5 ± 0.2 mV/decade over the range 1.0 × 10−9 to 5.0 × 10−1M at p...
متن کاملConstruction of Cu2+-selective electrode and thermodynamic study of the ternary aqueous mixed electrolyte system (CuCl2, KCl, H2O) using nanocomposite-based potentiometric sensor
A nanocomposite membrane Cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (ETMOC) as a neutral ionophore. The electrode works properly. It responds to Cu2+ ion with a sensitivity of 29.5 ± 0.2 mV/decade over the range 1.0 × 10−9 to 5.0 × 10−1M at p...
متن کاملDetermination and Modeling the Activity Coefficients of 1-Propyl-3- methylimidazolium Bromide in the Ethanol + Water Mixtures at T = (298.2, 308.2 and 318.2) K
In this work, the results relating to the mean activity coefficient measurements for ionic liquid of 1- propyl -3 methylimidazolium bromide, [PMIm]Br in ethanol+ water mixtures have been reported using potentiometric measurements at T=( 298.2, 308.2 and 318.2)K. The electromotive force (emf) measurements were performed on the galvanic cell of the type:Br-ISE│[PrMIm] (m) ethanol (wt.%), H2O (1−w...
متن کاملthermodynamic study of the ternary electrolyte (1-butyl-3-methylimidazolium chloride + sodium chloride + water) system using potentiometric measurements
in this paper, the thermodynamic properties of the aqueous mixed electrolyte system containing 1-butyl-3-methylimidazolium chloride ([bmim]cl) and nacl are reported based on the potentiometric method. the potentiometric measurements were performed on the galvanic cells without liquid junction of the type:ag-agcl [bmim]cl (m1), nacl(m2), h2o│il-ise, over total ionic strengths from 0.0025 to 2.00...
متن کاملconstruction of cu2+-selective electrode and thermodynamic study of the ternary aqueous mixed electrolyte system (cucl2, kcl, h2o) using nanocomposite-based potentiometric sensor
a nanocomposite membrane cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (etmoc) as a neutral ionophore. the electrode works properly. it responds to cu2+ ion with a sensitivity of 29.5 ± 0.2 mv/decade over the range 1.0 × 10−9 to 5.0 × 10−1m at ph 3.0-8.0. the limit of detection was 4.5 × ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 5 شماره 4
صفحات 783- 794
تاریخ انتشار 2017-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023