Manual maximum closing torque in three implant abutment systems
نویسندگان
چکیده مقاله:
Background and Aims: Diferences whithin shape and size of hand wrenches in diferent systems could affect the torque applied. Therefore, evaluation of wrenches has been emphasized. The aim of the present study was to compare the torque values of the long and short torque wrenches in different implant systems including ITI, Implantium and Nobel Biocare. Materials and Methods: In this experimental trial, 5 dentists with at least 5 years of professional experience closed the abutment screw in different implants systems using the long and short manual wrenches while the wrench-induced torque values were calculated by digital torque-meter. Torque application was done for 3 times with 10-minutes resting time between each wrench uses in the habitual closing torque manner. Data were analyzed using two-way analysis of variance test in different implant systems, while the paired comparisons were done using Tukey post hoc test. Results: The maximum torque values of the long manual wrenches were 27.73±4.57 Ncm, 34.6±8.09 Ncm and 30.6±6.94 Ncm for the ITI, Implantium, and Nobel Biocare systems, respectively. While the values were reported to be 26.4±5.3 Ncm, 35.27±7.94 Ncm and 30.13±5.26 Ncm in the short manual wrenches for the ITI, Implantium and Nobel Biocare systems, respectively. Significant differences were found between ITI and Implantium (P<0.0001), and between Implantium and Nobel Biocare systems (P<0.021). However, no significant differences were observed between ITI and Nobel Biocare systems regarding wrench-induced torque values (P>0.05). Conclusion: From the results, the torque values obtained by different long and short manual wrenches were specific to different implant systems. These values were less in ITI and Nobel Biocare systems and higher in implantun than those range provided for the implant systems by the companies.
منابع مشابه
In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening
Preload is applied to screws manually or using a torque wrench in dental implant systems, and the preload applied must be appropriate for the purpose. The aim of this study was to assess screw loosening and bending/torsional moments applied by clinicians of various specialties following application of manual tightening torque to combinations of implants and abutments. Ten-millimeter implants of...
متن کاملPreload and Torque Removal Evaluation of Three Different Abutment Screws for Single Standing Implant Restorations
Several authors still consider the mechanical problems of fracture and component loosening as the main causes of failure of implant-supported restorations. The purpose of this in vitro study was to compare the preload of three types of screw for transmucosal abutment attachment used in single implant-supported prosthesis through strain gauge and removal torque measurements. Three external hex f...
متن کاملRelation between implant/abutment vertical misfit and torque loss of abutment screws.
This study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four frameworks were waxed using UCLA type abutments and one-piece cast in commercially pure...
متن کاملMarginal accuracy of three implant-ceramic abutment configurations.
PURPOSE Microgaps at the implant-abutment interface allow for microbial colonization, which can lead to peri-implant tissue inflammation. This study sought to determine the marginal accuracy of three different implant-zirconium oxide (zirconia) abutment configurations and one implant?titanium abutment configuration. MATERIALS AND METHODS Three combinations of implants with custom-made zirconi...
متن کاملResistance of three implant-abutment interfaces to fatigue testing
UNLABELLED The design and retentive properties of implant-abutment connectors affect the mechanical resistance of implants. A number of studies have been carried out to compare the efficacy of connecting mechanisms between abutment and fixture. OBJECTIVES The aims of this study were: 1) to compare 3 implant-abutment interfaces (external hexagon, internal hexagon and cone-in-cone) regarding th...
متن کاملInfluence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems
PURPOSE This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), c...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 32 شماره 2
صفحات 75- 82
تاریخ انتشار 2019-10
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی برای این مقاله ارائه نشده است
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023