Magnetic Calibration of Three-Axis Strapdown Magnetometers for Applications in Mems Attitude-Heading Reference Systems

نویسندگان

  • Hamed Milanchian Department of Mechanical Engineering, University of Tabriz, Tabriz, Iran
  • Jafar Keighobadi Department of Mechanical Engineering, University of Tabriz, Tabriz, Iran
چکیده مقاله:

In a strapdown magnetic compass, heading angle is estimated using the Earth's magnetic field measured by Three-Axis Magnetometers (TAM). However, due to several inevitable errors in the magnetic system, such as sensitivity errors, non-orthogonal and misalignment errors, hard iron and soft iron errors, measurement noises and local magnetic fields, there are large error between the magnetometers' outputs and actual geomagnetic field vector. This is the necessity of magnetic calibration of TAM, especially in navigation application to achieve the true heading angle. In this paper, two methodologies, including clustering swinging method and clustering velocity vector method are presented for magnetic compass calibration. Several factors for clustering process have been introduced and analyzed. The algorithms can be applied in both low-cost MEMS magnetometer and high-accuracy magnetic sensors. The proposed calibration algorithms have been evaluated using in-ground and in-flight tests. It can be concluded from the experimental results that, applying the clustering calibration algorithms bring about a considerable enhancement in the accuracy of magnetic heading angle

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

magnetic calibration of three-axis strapdown magnetometers for applications in mems attitude-heading reference systems

in a strapdown magnetic compass, heading angle is estimated using the earth's magnetic field measured by three-axis magnetometers (tam). however, due to several inevitable errors in the magnetic system, such as sensitivity errors, non-orthogonal and misalignment errors, hard iron and soft iron errors, measurement noises and local magnetic fields, there are large error between the magnetometers'...

متن کامل

Magnetic Calibration of Three-Axis Strapdown Magnetometers for Applications in Mems Attitude- Heading Reference Systems

In a strapdown magnetic compass, heading angle is estimated using the Earth's magnetic field measured by Three-Axis Magnetometers (TAM). However, due to several inevitable errors in the magnetic system, such as sensitivity errors, non-orthogonal and misalignment errors, hard iron and soft iron errors, measurement noises and local magnetic fields, there are large error between the magnetometers'...

متن کامل

Calibration of Strapdown Magnetometers in the Magnetic Field Domain

This paper presents an algorithm for calibrating strapdown magnetometers in the magnetic field domain. In contrast to the traditional method of compass swinging, which computes a series of heading correction parameters and, thus, is limited to use with two-axis systems, this algorithm estimates magnetometer output errors directly. Therefore, this new algorithm can be used to calibrate a full th...

متن کامل

A low-cost attitude heading reference system by combination of GPS and magnetometers and MEMS inertial sensors for mobile applications

This paper describes a prototype system for attitude and heading determination. A L1-only GPS receiver is integrated with microelectromechanical gyroscopes, accelerometers and magnetometers. In contrast to a multi-antenna/multi-receiver GPS attitude determination system, this system uses a single antenna/single receiver configuration to derive standalone velocity and acceleration solutions from...

متن کامل

A novel method to integrate IMU and magnetometers in attitude and heading reference systems

Modern attitude and heading reference systems (AHRS) generally use Kalman Filter to integrate gyros with some other augmenting sensors, such as accelerometers and magnetometers, to provide a long term stable orientation solution. The construction of the Kalman Filter for the AHRS is flexible, while the general options are the methods based on quaternion, Euler angles, or Euler angle errors. But...

متن کامل

Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer

A complete error calibration model with 12 independent parameters is established by analyzing the three-axis magnetometer error mechanism. The said model conforms to an ellipsoid restriction, the parameters of the ellipsoid equation are estimated, and the ellipsoid coefficient matrix is derived. However, the calibration matrix cannot be determined completely, as there are fewer ellipsoid parame...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 47  شماره 1

صفحات  55- 65

تاریخ انتشار 2015-05-22

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.