Longitudinal Conduction in Cross Flow Heat Exchanger with Condensation

نویسنده

چکیده مقاله:

The deterioration of the performance of a cross flow heat exchanger with condensation due to the longitudinal conduction was investigated. For a relatively small change of wall temperature along the flow directions which was shown to be common in many applications, the energy equations were solved numerically. An iterative method was used to solve the resulting equations of the finite difference form in Order to obtain the hot fluid, the cold fluid and the wall temperature distributions and the exchanger thermal effectiveness. A comparison was made between the effects of longitudinal conduction on the exchanger performance, without and with condensation. The results indicated that with the same values of NTU, the capacity ratio and the conduction parameter, λ, the performance deterioration of a cross flow heat exchanger with condensation is not as strong as the case of pure heat transfer.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artificial Neural Network Modeling of Heat Transfer in a Staggered Cross-flow Tube-type Heat Exchanger

This paper presents the application of Artificial Neural Network (ANN) in modeling the heat transfer coefficient of a staggered multi-row, multicolumn, cross-flow, tube-type heat exchanger. Heat transfer data were obtained experimentally for air flowing over a bank of copper tubes arranged in staggered configuration with 5 rows and 4 columns at different air flow rates with throttle valve openi...

متن کامل

Flow and Pressure Distributions in Short Heat Exchanger Cores with Abrupt Entrance and Exit

The typical installation of a heat exchange device usually involves a flow contraction at the core entrance and a flow expansion at the core exit. Repeated flow Contraction and expansion are experienced in the flow passages of some compact heat exchangers. The latter refers to the flow passages in the plate-fin type with louvered fins or stripped fins and in the tubular type with dimpled-circul...

متن کامل

Evaporation and Condensation Heat Transfer Performance of Flammable Refrigerants in a Brazed Plate Heat Exchanger

Average Nusselt numbers were measured for R22, R290, R290/600a, and R32/152a undergoing evaporation and condensation in a brazed plate heat exchanger. The refrigerants experienced wavy, stratified flow at low heat and mass fluxes, 1.3 kW/m2 to 8.3 kW/m2 and 1.6 kg/m2 s to 19 kg/m 2 s, respectively. Heat transfer correlations from the literature for in-tube and channel flow of refrigerants with ...

متن کامل

Finite Volume Solution of a Cylinder in Cross Flow with Heat Transfer

A finite-volume model has been developed to study incompressible forced flow heat transfer of air over a circular cylinder in cross flow. An artificial compressibility technique is applied to couple the continuity to the momentum equations. The proposed explicit finite-volume method (FVM) uses a novel discretization in time and space. The governing equations are solved by time-marching using a ...

متن کامل

Experimental and Numerical Analysis of Flow and Heat Transfer in a Gas-Liquid Thermosyphon Heat Exchanger in a Pilot Plant

A numerical and experimental investigation of flow and heat transfer in a gas- liquid Thermosyphon Heat Exchanger "THE" with built in heat pipes and aluminum plate fins for moderate Reynolds numbers has been carried out. It's module is composed of 6 rows and 15 columns copper pipes with aluminum plate fins with dimensions of 130cm height, 47cm width and  20cm depth. The tubes have been fill...

متن کامل

Heat Transfer and Pressure Drop During HC-600a (Isobutane) Condensation Inside a Brazed Plate Heat Exchanger

This paper presents the heat transfer coefficients and the pressure drop measured during HC-600a (Isobutane) condensation inside a brazed plate heat exchanger: the effects of saturation temperature, refrigerant mass flux and vapour super-heating are investigated. The heat transfer coefficients show weak sensitivity to saturation temperature and great sensitivity to refrigerant mass flux. At low...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 1  شماره 2

صفحات  129- 138

تاریخ انتشار 1988-08-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023