Local Scour at Single Column Arrangement of Bridge Piles Group

نویسندگان

  • Gohari, S. 1. Department of Water Engineering, College of Agriculture, Bu-Ali Sina University, Hamadan, Iran
  • Okhravi, S. 1. Department of Water Engineering, College of Agriculture, Bu-Ali Sina University, Hamadan, Iran
چکیده مقاله:

In regard to wide piers, the pile group rather than single pile is used frequently to bear the loading of the structure in a particular arrangement; piles group composed of only one column of piles in the flow direction has a great effect on supporting the bridge deck. In this study, local scour at a single column arrangement of the piles group made up of four rows of piles characterized by different piles spacing was studied for clear-water conditions with two flow discharges of 20 and 35 l/s (the effect of increasing the flow depth with the same flow intensity). The results indicated that an increase in the flow depth not only greatly enhanced the scour depth and the width of the scour hole. Besides, the investigation of the relative flow depth on scour extent showed the need for revision in deep water conditions, as reported in the literature. The results of the pile group experiments revealed the noticeable impacts of piles spacing on the local scour. The bigger pile spacing caused a feeble interaction of wake-horseshoe vortices, leading to a decrease of the scour depth; the separate view of the scour holes was generated at individual piles. Finally, the results were compared with commonly used comprehensive models. The findings of this study can be applied for the appropriate selection and positioning for the countermeasure of the scour at bridge piers.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time Development of Local Scour around Semi Integral Bridge Piers and Piles in Malaysia

Scouring around a bridge pier is a complex phenomenon. More laboratory experiments are required to understand the scour mechanism. This paper focused on time development of local scour around piers and piles in semi integral bridges. Laboratory data collected at Hydraulics Laboratory, University of Malaya was analyzed for this purpose. Tests were performed with two different uniform sediment si...

متن کامل

scour modeling piles of kambuzia industrial city bridge using hec-ras and artificial neural network

today, scouring is one of the important topics in the river and coastal engineering so that the most destruction in the bridges is occurred due to this phenomenon. whereas the bridges are assumed as the most important connecting structures in the communications roads in the country and their importance is doubled while floodwater, thus exact design and maintenance thereof is very crucial. f...

Reducing Local Scouring at Bridge Piles Using Collars and Geobags

The present study examines the use of collars and geobags for reducing local scour around bridge piles. The efficiency of collars and geobags was studied experimentally. The data from the experiments were compared with data from earlier studies on the use of single piles with a collar and with a geobag. The results showed that using a combination of a steel collar and a geobag yields the most s...

متن کامل

Countermeasures against Scour at Bridge Abutments

HUA LI. Countermeasures against Scour at Bridge Abutments (Under the direction of Dr. BRIAN D. BARKDOLL) Scour at bridge abutments can cause damage or failure of bridges and result in excessive repairs, loss of accessibility, or even death. To mitigate abutment scour, both clear-water and live-bed laboratory experiments in a compound channel were performed using parallel walls and spur dikes as...

متن کامل

Experimental comparison of sacrificial piles and submerged vanes as scour countermeasures around bridge pier

An experimental study has been conducted on the effectiveness of two types of flow-altering countermeasures placed around a cylindrical pier under clear water condition, which include sacrificial piles and submerged vanes. Their arrangements follow the optimal configurations recommended in the published articles with some modification. The temporal evolution of maximum scour depth and its equil...

متن کامل

Bridge Local Scour Monitoring System Using MEMS Sensor Zigbee Network

Wireless MEMS sensors network has been widely used in many fields. In this paper the MEMS pressure sensor is integrated on a sensor board with Zigbee sensor network for real-time local bridge scour depth monitoring during a flood. The wireless MEMS pressure sensor scour monitoring system has been developed and tested in the laboratory. Local scour is one of the major factors for bridge failure....

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 24  شماره 4

صفحات  57- 73

تاریخ انتشار 2021-02

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023