Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

نویسندگان

  • Jun Ma General Hospital of Lanzhou command of PLA
  • Jun Ren General Hospital of Lanzhou command of PLA
چکیده مقاله:

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was approximately 7 min. The autosampler was set with an injection volume of 10 μl. The calibration curve was linear in the concentration range of 0.1~15.0 µg/mL. The coefficient of determination (r) was greater than 0.9998. This method has been fully validated and shown to be specific, accurate and precise. The method was simple, rapid and the sample preparation was minimal. It was successfully applied to the analysis of healthy volunteer serum samples during a phaseⅠclinical pharmacokinetic study of fudosteine.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

liquid chromatography tandem mass/mass spectrometry for the quantification of fudosteine in human serum without precolumn derivatization

a quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (hplc-esi/ms/ms) was established, which shows high sensitivity and selectivity. the mobile phase composition was 75% 20 mm acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 ml/min. the overall chromatographic run time was ...

متن کامل

Sensitive quantification of bulleyaconitine A in human serum by liquid chromatography-tandem mass spectrometry.

A simple and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for the quantification of bulleyaconitine A (BLA) in human serum. Samples were extracted from human serum by protein precipitation. Domperidone was used as internal standard (I.S.). Chromatography separation was performed on a Waters Sunfire C18 column (2.1 x 50 mm, 5 microm) with...

متن کامل

Liquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...

متن کامل

Determination of Mebudipine in Human Plasma by Liquid Chromatography–tandem Mass Spectrometry

In previous studies, mebudipine, a dihydropyridine calcium channel blocker, showed a considerable potential to be used in cardiovascular diseases. The aim of the current study was to develop a valid method using reversed-phase high performance liquid chromatography coupled with electrospray ionization mass spectrometry to assay mebudipine in the human plasma. Separation was achieved on a Zorbax...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 13  شماره 2

صفحات  441- 447

تاریخ انتشار 2014-06-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023