Laboratory Monitoring of Cyclosporine Pre-dose Concentration (C0) After Kidney Transplantation in Isfahan

نویسندگان

  • A.A. Palizban School of Pharmacy, Isfahan University of Medical Sciences and Health Services, Isfahan, Iran.
  • Z. Tolou-Ghamari School of Pharmacy, Isfahan University of Medical Sciences and Health Services, Isfahan, Iran.
چکیده مقاله:

Background: Cyclosporine is the main immunosuppressive agent used in organ transplantation which leads to considerable improvement in graft survival.  The large inter- and intra- patient variability in cyclosporine pharmacokinetics coupled with the agent’s narrow therapeutic index and adverse effects necessitate therapeutic monitoring of cyclosporine blood levels. Objective: The aim of this study was to determine the extent of variability following oral administration of cyclosporine after kidney transplantation, and provide guidelines for administration of cyclosporine in Isfahan/Iran Methods: The results of 2163 cyclosporine pre-dose blood samples obtained from 647 kidney transplant recipients (208 females, 439 males) with a median age of 34 years (range 11-54 years) were studied. Concentration of cyclosporine in the whole blood was determined by a radioimmunoassay using monoclonal antibodies specific for the drug. Statistical analyses were performed using SPSS. Results: The frequency distribution of C0 and daily oral dosage of cyclosporine exhibited wide interindividual variability.  Cyclosporine oral dosage regimen ranged from 100 mg to 400 mg.  Trough cyclosporine blood concentration (C0) ranged from 18 ug/l to 1400 ug/l. The results of cyclosporine whole blood levels in 56% were always below the suggested therapeutic range (less than 200 ug/l) and in 14% of the samples seemed to be associated with the occurrence of toxic side effects.  There were no significant differences in the median trough levels of kidney recipients according to gender (p = 0.36). Conclusion: For long-term management of kidney transplant recipients and in order to further optimize the use of cyclosporine, it is essential to standardize laboratory monitoring and clinical investigation of this agent.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

laboratory monitoring of cyclosporine pre-dose concentration (c0) after kidney transplantation in isfahan

background: cyclosporine is the main immunosuppressive agent used in organ transplantation which leads to considerable improvement in graft survival.  the large inter- and intra- patient variability in cyclosporine pharmacokinetics coupled with the agent’s narrow therapeutic index and adverse effects necessitate therapeutic monitoring of cyclosporine blood levels.   objective: the aim of this s...

متن کامل

The Relationship between the Plasma Level of Cyclosporine-A and Drug Dose in Patients of Kermanshah Kidney Transplantation Center

Background: Nowadays the main problem in transplantation is the complexity of host immune system protection against the immunological and destructive reactions of the transplanted organ. High serum level of the immunosuppressive drug may cause toxicity and low serum level leads to the rejection of the transplanted organ. Cyclosporine has been known as the most effective immunosuppressive drug. ...

متن کامل

Cyclosporine C0- versus C2-monitoring over three years in maintenance heart transplantation.

INTRODUCTION There is an ongoing discussion as to whether monitoring of cyclosporine (CsA)-based immunosuppression with plasma levels two hours after medication intake (C2) offers clinical benefit over the measurement of CsA trough levels (C0) in patients after heart transplantation (HTx). In particular, data from long-term maintenance patients are not available. METHODS C0 monitoring was per...

متن کامل

change of cyclosporine absorption over the time after kidney transplantation

background although the immunosuppressant cyclosporine (csa) is widely used after kidney transplantation over the long term, there is still no firm consensus on the best way to monitor of csa blood levels. objectives cyclosporine (csa) assay is critical for the management of renal transplant recipients due to inter– and intra–patient variation in csa absorption and metabolism. patients and meth...

متن کامل

NINE CASES OF MALIGNANCY AFTER KIDNEY TRANSPLANTATION

Renal transplantation is considered one of the best long-term therapies for chronic renal failure, but unfortunately the incidence of malignancy significantly increases in renal transplant recipients. We analyzed nine cases of malignancy in 200 renal transplant recipients occurring in a 12-year follow-up in Imam hospital of Tehran University, Tehran, Iran. According to this study, the organ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 28  شماره 2

صفحات  81- 85

تاریخ انتشار 2015-10-28

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023