Investigation of Wear Behavior of Biopolymers for Total Knee Replacements Through Invitro Experimentation
نویسندگان
چکیده مقاله:
The average life span of knee prosthesis used in Total Knee Replacement (TKR) is approximately 10 to 15 years. Literature indicates that the reasons for implant failures include wear, infection, instability, and stiffness. However, the majority of failures are due to wear and tear of the prosthesis. The most common biopolymer used in TKR is Ultra High Molecular Weight Polyethylene (UHMWPE). Prevailing research reports that implants are restrained by tiny UHMWPE debris generated by long term friction between the femoral component and polyethylene articulating surface. This necessitates an alternative material with high wear-resistance to reduce the wear rate. Polyether ether ketone (PEEK) is one of the biopolymers expected to possess better mechanical properties and biocompatibility with surrounding tissue and hence can be suitable for orthopedic applications. In this regard, a study on UHMWPE and PEEK biopolymers was carried out and tribological behavior was examined. The effect of process parameters such as normal load and speed on the tribological performance of biopolymers were evaluated. The experiment plan was designed as per Taguchi’s Design of Experiments methodology. An empirical relation between wear and process parameters was established using linear regression analysis. Microanalysis and failure analysis of worn-out surfaces of both the biopolymers was carried out using Scanning Electron Microscopy(SEM). Results exhibit that UHMWPE had deep grooves as compared to finer grooves on PEEK indicating a low wear rate in the latter. This was also supported by the experimental results suggesting PEEK as a suitable alternative biopolymer for TKR.
منابع مشابه
Simulating Wear On Total Knee Replacements
Wear on total knee replacements (TKRs) is an important criterion for their performance characteristics. Numerical simulations of such wear has seen increasing attention over the last years. They have the potential to be much faster and less expensive than the in vitro tests in use today. While it is unlikely that in silico tests will replace actual physical tests in the foreseeable future, a ju...
متن کاملComputational Prediction of in Vivo Wear in Total Knee Replacements
INTRODUCTION Wear of ultra-high molecular weight polyethylene (UHMWPE) in total knee replacements remains a major limitation to the longevity of these clinically successful devices [1]. Improvements in sterilization techniques over the past decade have reduced oxidative degradation of the UHMWPE bearing, with potentially dramatic long-term reductions in fatigue-related pitting and delamination ...
متن کاملWear Comparison of Fixed vs. Mobile Bearing Total Knee Replacements
INTRODUCTION: The debate between fixed-bearing and mobile-bearing systems continues due to the lack of clinical evidence showing survivorship of one to be superior to the other [1,2]. Delport et al report similar tibiofemoral kinematic patterns with respect to axial rotation during flexion and also femorotibial translation [3]. Conversely, Huang et al show a significant difference between the t...
متن کاملA comparison between electromechanical and pneumatic-controlled knee simulators for the investigation of wear of total knee replacements
More robust preclinical experimental wear simulation methods are required in order to simulate a wider range of activities, observed in different patient populations such as younger more active patients, as well as to fully meet and be capable of going well beyond the existing requirements of the relevant international standards. A new six-station electromechanically driven simulator (Simulatio...
متن کاملCurrent Concepts Review Wear in Total Hip and Knee Replacements
Before the advent of total joint replacement, patients who had end-stage arthritis of the lower extremities had unremitting pain and a greatly decreased functional capacity. In addition, they often were confined to a wheelchair and were dependent on the care of others. Today, the outcomes of primary total hip and knee replacement are predictable and usually excellent. Prosthetic joint replaceme...
متن کاملA comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements
A more robust pre-clinical wear simulation framework is required in order to simulate wider and higher ranges of activities, observed in different patient populations such as younger more active patients. Such a framework will help to understand and address the reported higher failure rates for younger and more active patients (National_Joint_Registry, 2016). The current study has developed and...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 33 شماره 8
صفحات 1560- 1566
تاریخ انتشار 2020-08-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023