Investigation of physical penumbra definition in treatment planning

نویسندگان

  • H. Alipour Department of Nuclear Engineering, Faculty of Mechanical Engineering, Shiraz University, Shiraz, Iran
  • K. Hadad Department of Nuclear Engineering, Faculty of Mechanical Engineering, Shiraz University, Shiraz, Iran
  • R. Faghihi Department of Nuclear Engineering, Faculty of Mechanical Engineering, Shiraz University, Shiraz, Iran
چکیده مقاله:

Background: Due to the small size of the beamlets in IMRT (intensity modulated radiotherapy), physical penumbra is one of the important dosimetric parameters and small changes in the penumbra have a notable impact on the results. The physical penumbra width is defined as the lateral distance between two specified isodose curves at a specified depth of phantom. In this study, after demonstrating the inconsistency of conventional physical penumbra definition for non-uniform MLC (multileaf collimator) fields, two new dosimetric parameters proposed that are suitable for MLC fields. Materials and Methods: Physical penumbra evaluation was obtained using IAEA (international atomic energy agency) phase space data for a Varian IX and EGS (electron gamma shower)nrc Monte Carlo code package.  These measurements have been performed in water phantom at an SSD of 100 cm and a depth of 5 cm. Results: With conventional definition, physical penumbra width for all MLC setups on right and left sides of isodose curves (parallel to X and Y axes) are not equal.  With a novel beam penumbra parametrization, the effect of MLC setup is taken into consideration. Conclusion: The conventional definition of physical penumbra for non-uniform MLC setups is not comprehensive. For such cases, surface penumbra and uniformity index parameters are demonstrated to be more suitable and indicative of the field non-uniformity. It is also shown that for an idle treatment planning system, the uniformity index approaches unity.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of physical penumbra definition in IMRT applications

Introduction: Because of small size of the beamlets in IMRT, physical penumbra is one of the important dosimetric parameters and small changes in the penumbra will have a great impact on the results. The physical penumbra width is defined as the lateral distance between two specified isodose curves at a specified depth of phantom. In this study, after demonstrating the inconsi...

متن کامل

investigation of (meta)discourse markers in elt coursebooks

the present study aimed to investigate representation of discourse markers and metadiscourse markers in conversations and readings of general elt coursebook series used in the language centers of iran. to this aim, four elt coursebooks popularly taught in language centers of this country were analyzed based on fung and carter’s (2007) framework regarding discourse markers and hyland’s (2005) fr...

Assessment of Dose Calculation Accuracy of TiGRT Treatment Planning System for Physical Wedged fields in Radiotherapy

Introduction Wedge modifiers are commonly applied in external beam radiotherapy to change the dose distribution corresponding to the body contour and to obtain a uniform dose distribution within the target volume. Since the radiation dose delivered to the target must be within ±5% of the prescribed dose, accurate dose calculation by a treatment planning system (TPS) is important. The objective ...

متن کامل

Optimum reckoning of contra lateral breast dose using physical wedge and enhanced dynamic wedge in radiotherapy treatment planning system

Background: It was intended to investigate the effect of physical wedge (PW) and enhanced dynamic wedges (EDW) on contralateral breast dose during primary breast irradiation in radiotherapy treatment, using high energy photon beams. Materials and Methods: The Varian’s Clinac dual mode linear accelerator model 2100 C/D and Siemen’s Primus accelerators were used for radiation doses wi...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 17  شماره 3

صفحات  485- 489

تاریخ انتشار 2019-06

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023