Investigation of physical penumbra definition in IMRT applications

نویسندگان

  • Kamal Hadad 1Department of Nuclear Engineering, Shiraz University, Faculty of Mechanical Engineering,
  • Reza Faghihi Department of Nuclear Engineering, Shiraz University, Faculty of Mechanical Engineering,
چکیده مقاله:

Introduction: Because of small size of the beamlets in IMRT, physical penumbra is one of the important dosimetric parameters and small changes in the penumbra will have a great impact on the results. The physical penumbra width is defined as the lateral distance between two specified isodose curves at a specified depth of phantom. In this study, after demonstrating the inconsistency of conventional physical penumbra definition for non-uniform MLC fields, two new dosimetric parameters proposed, those are intended to be suitable for MLC fields   Materials and Methods: Physical penumbra evaluation was obtained using IAEA phase space data for a Varian IX and EGSnrc Monte Carlo code package. The homogenous water phantom is located at SSD=100 cm. Results: With conventional definition, physical penumbra widths for all MLC setups on right and left sides of isodose curves (parallel to X and Y axes) are not equal. With the proposed dosimetric parameters, the effect of MLC setup is taken into consideration. Conclusion: The intended purpose from physical penumbra in its conventional definition is not satisfied for non-uniform MLC setups. For such cases, the newly defined surface penumbra and uniformity index are demonstrated to be more suitable and indicative of the field non-uniformity. It is also shown that for an idle treatment planning system, the uniformity index approaches unity.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of physical penumbra definition in treatment planning

Background: Due to the small size of the beamlets in IMRT (intensity modulated radiotherapy), physical penumbra is one of the important dosimetric parameters and small changes in the penumbra have a notable impact on the results. The physical penumbra width is defined as the lateral distance between two specified isodose curves at a specified depth of phantom. In this study, after demonstrating...

متن کامل

investigation of (meta)discourse markers in elt coursebooks

the present study aimed to investigate representation of discourse markers and metadiscourse markers in conversations and readings of general elt coursebook series used in the language centers of iran. to this aim, four elt coursebooks popularly taught in language centers of this country were analyzed based on fung and carter’s (2007) framework regarding discourse markers and hyland’s (2005) fr...

Physical and dosimetric characteristic of high‐definition multileaf collimator (HDMLC) for SRS and IMRT

Physical and dosimetric characteristics of HDMLC were studied for SRS6, 6, and 10 MV X-rays from Novalis Tx. This in-built tertiary collimator consists of 60 pairs (32 × 0.25 cm; 26 × 0.5 cm and 2 × 0.7 cm) of leaves. Properties of HDMLC studied included alignment, readout and radiation field congruence, radiation penumbra, accuracy and reproducibility of leaf position and gap width, static and...

متن کامل

an investigation of accuracy and complexity across different proficiency levels in written narrative task

abstract this quasi-experimental study was aimed at examining the impact of storyline complexity on the grammatical accuracy and complexity of advanced and intermediate efl learners. a total of 65 advanced and intermediate efl learners were selected from iran language institute (ili). an intact group including 35 intermediate participants and another intact group with 30 advanced participants ...

an investigation into iranian teachers consistency and bias in evaluation of students writings

while performance-based language assessment has led to an increased authenticity and content validity in the practice of writing assessment, the reliability of ratings has become a major issue. research findings have shown different reactions by native english speaker (nes) and non-native english speaker (nns) teachers to students’ writings. the focus of this study is on investigating whether i...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  167- 167

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com