Investigation of Behavior of Forced Degradation of Lidocaine HCl by NMR Spectroscopy and GC-FID Methods: Validation of GC-FID Method for Determination of Related Substance in Pharmaceutical Formulations
نویسندگان
چکیده مقاله:
The forced degradation study of lidocaine HCl was carried out according to the ICH guideline Q1A (R2). The degradation conditions were assessed to be hydrolysis, oxidation, photolysis and dry heat during 24 h, 48 h and 72 h and then the samples were investigated by GC-FID method and nuclear magnetic resonance (NMR) spectroscopy. According to these results, the degradation products were not observed in all reaction conditions during the 72 h period. Only spectral changes in the 1H and 13C-NMR spectrum were observed in hydrogen peroxide and acid degradation. As a result of this degradation, n-oxide was formed. After acid-induced degradation with HCl, the secondary amine salt was formed. Furthermore, trifluoroacetic acid (TFA) was used as the acidic media, and the decomposition products were observed. A simple and reliable gas chromatography method with flame ionization detection (GC-FID) was developed and validated for the determination of lidocaine HCl in pharmaceutical formulations in the form of a cream and injections. The GC-FID method can be used for a routine analysis of lidocaine HCl in pharmaceutical formulations and the proposed method, together with NMR spectroscopy, can be applied in stability studies.
منابع مشابه
investigation of behavior of forced degradation of lidocaine hcl by nmr spectroscopy and gc-fid methods: validation of gc-fid method for determination of related substance in pharmaceutical formulations
the forced degradation study of lidocaine hcl was carried out according to the ich guideline q1a (r2). the degradation conditions were assessed to be hydrolysis, oxidation, photolysis and dry heat during 24 h, 48 h and 72 h and then the samples were investigated by gc-fid method and nuclear magnetic resonance (nmr) spectroscopy. according to these results, the degradation products were not obse...
متن کاملInvestigation of Behavior of Forced Degradation of Lidocaine HCl by NMR Spectroscopy and GC-FID Methods: Validation of GC-FID Method for Determination of Related Substance in Pharmaceutical Formulations
The forced degradation study of lidocaine HCl was carried out according to the ICH guideline Q1A (R2). The degradation conditions were assessed to be hydrolysis, oxidation, photolysis and dry heat during 24 h, 48 h and 72 h and then the samples were investigated by GC-FID method and nuclear magnetic resonance (NMR) spectroscopy. According to these results, the degradation products were not obse...
متن کاملDevelopment and Validation of a GC-FID Method for Diagnosis of Methylmalonic Acidemia
Background: Urinary organic acids are water-soluble intermediates and end products of the metabolism of amino acids, carbohydrates, lipids, and a number of other metabolic processes. In the hereditary diseases known as organic acidurias, an enzyme or co-factor defect in a metabolic pathway leads to the accumulation and increased excretion of one or more of these acidic metabolites. Gas chromato...
متن کاملdetermination of olanzapine and thiourea using electrodes modified by dna and film of copper-cobalt hexacyanoferrate & investigation of electro-oxidation of some catechol derivatives in the presence of 4-phenylsemicarbazid
چکیده هدف از این کار بررسی الکترواکسیداسیون کتکول و مشتقات آن در حضور 4-فنیل سمی کاربامازید بوده است اکسیداسیون کتکولها ترکیبات نا پایدار کینونها را تولید می کنند که این ترکیبات می تواند در واکنش مایکل بعنوان پذیرنده نوکلئوفیل عمل نمایند. در ادامه اکسایش کتکولهای (a-c1) را درحضور 4-فنیل سمی کاربامازید در محلول آب/استونیتریل (90/10)بوسیله ولتامتری چرخه ای و کولن متری در پتانسیل ثابت مورد بررسی ...
15 صفحه اولDevelopment and Validation of a Gc-fid Assay for Determination of Fluvastatin in Pharmaceutical Preparations
A gas chromatographic method has been developed for the assay of fluvastatin sodium (FLU). FLU was silylated with N,Obis(trimethylsilyl)trifluoroacetamide-1% trimethylchlorosilane at 90 oC for 30 min and analysed in a DB-1 column by capillary gas chromatograph with a flame ionization detector. The method was validated. The assay was linear over the concentration range at 10.0 to 50.0 mg mL. The...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 12 شماره 4
صفحات 659- 669
تاریخ انتشار 2013-11-01