Investigation of a single-reheat condensing steam power plant based on energy and exergy analysis
نویسندگان
چکیده مقاله:
Nowadays, energy plays an important role in the economic and community development of country. Consequently, performance analysis of energy systems is one of the effective methods being used to prevent waste of energy resources. Among the different power generation technologies, steam power plants make a significant contribution to power generation in Iran, with a share of 47 % of electricity generation. Therefore, it seems that exergy analysis of the power plant can help designers to reduce energy losses and increase efficiency. In this study, energy and exergy analysis of a single-reheat steam power plant in Iran is presented. This analysis considered the effect of environment temperature variation on the energy and exergy efficiencies. The results showed that the condenser has most energy losses (50%) in a cycle, while maximum exergy destruction (84%) occurs in the boiler. The thermal and exergy efficiencies at reference temperature were computed as 36.84% and 34.75%, respectively. Exergy destruction and efficiency of each component have been considered and are reported in the paper. The effects of various parameters such as steam pressure, steam temperature and condenser pressure have also been examined in the cycle performance.
منابع مشابه
Investigation of a Single-reheat Condensing Steam Power Plant Based on Energy and Exergy Analysis
Nowadays, energy plays an important role in the economic and community development of country. Consequently, performance analysis of energy systems is one of the effective methods being used to prevent waste of energy resources. Among the different power generation technologies, steam power plants make a significant contribution to power generation in Iran, with a share of 47 % of electricity g...
متن کاملinvestigation of a single-reheat condensing steam power plant based on energy and exergy analysis
nowadays, energy plays an important role in the economic and community development of country. consequently, performance analysis of energy systems is one of the effective methods being used to prevent waste of energy resources. among the different power generation technologies, steam power plants make a significant contribution to power generation in iran, with a share of 47 % of electricity g...
متن کاملinvestigation of a single-reheat condensing steam power plant based on energy and exergy analysis
nowadays, energy plays an important role in the economic and community development of country. consequently, performance analysis of energy systems is one of the effective methods being used to prevent waste of energy resources. among the different power generation technologies, steam power plants make a significant contribution to power generation in iran, with a share of 47 % of electricity g...
متن کاملEnergy and Exergy Analysis of a Reheat Regenerative Vapor Power Cycle
The present paper describes the energy and exergy analysis of a reheat regenerative vapor power cycle. The plant consists of one boiler feed pump, one supercritical boiler, two steam turbines with a reheater in between, two feed water heaters (one open and one closed) and a condenser. The energy and exergy balance study has been carried-out for each component of the plant. Energy efficiency, ex...
متن کاملEnergy and Exergy Analysis of a New Power, Heating, Oxygen and Hydrogen Cogeneration Cycle Based on the Sabalan Geothermal Wells
In this paper, a new power, heating and hydrogen cogeneration cycle from Sabalan geothermal two wells is proposed and analyzed. In the proposed system, a new double flash cycle and organic Rankine cycle are used for power production. A proton exchange membrane (PEM) is also used for hydrogen production and the domestic water heater is used for heating. The impacts of some design parameters, suc...
متن کاملPerformance of Derna Steam Power Plant at Varying Super-Heater Operating Conditions Based on Exergy
Abstract—In the current study, energy and exergy analysis of a 65 MW steam power plant was carried out. This study investigated the effect of variations of overall conductance of the super heater on the performance of an existing steam power plant located in Derna, Libya. The performance of the power plant was estimated by a mathematical modelling which considers the off-design operating condit...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 2 شماره 2
صفحات 155- 170
تاریخ انتشار 2014-07-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023