Increased Absorption Dose with the Presence of Gold Nano particles in a Normoxic Polymer Gel: Method Monte Carlo
نویسندگان
چکیده مقاله:
Introduction: Radiotherapy involves all methods that can provide a special amount of ionizing radiation to malignant tissue with the assumption that minimal damage to healthy tissues is achieved. We are looking for a valuable and reliable method to measure the absorption dose and also the ability to measure the absorption dose distribution in three dimensions, which today is the only three-dimensional dosimeter the use of radiation- sensitive polymer gels. The purpose of this study was to calculate the amount of increase in absorbed dose with the presence of nanoparticles the gold is uniformly atomic in the polymer gel, with a high atomic number. According to the rules of photon interaction with matter, the probability Photovoltaic absorption is approximately equal to the third power of atomic matter of the target material, and has a direct relation with the third power of photon energy. Hence, the use of gold nanoparticles with high atomic numbers along with low-energy photon rays to increase absorption dose. Materials and Methods: Montecarlo calculations were performed to determine the absorption dose due to iridium -192 source with MCNPX code. From the gel Polymer-type neuro- muscular as a phantom to measure the amount of increased absorbing dose by adding nanoparticles of gold in a polymer gel uniformed with various concentrations under the irradiation -192 radiation rays Results: By increasing the gold nanoparticles in polymer gels with a concentration of 0.1mM to 1.5mM, the maximum absorption dose from 1% to 11% in energy 1.1Mev increases gamma rays. Also, in 0.65MeV energy, the increase is similar to the previous one. Conclusion: The results of this study, which was obtained by simulation, show that the optimum concentration of nanoparticles the gold in the polymer gel has a uniformly uniform type of protein to achieve a maximum absorbance dose of 1.5mM with increasing 11% in energies of 0.65MeV and 1.1MeV. The results show that the polymorphic gel of the Normoxic type can be called phantom of the soft tissue of the human body and the addition of gold nanoparticles with high atomic number and the concentration obtained can be the highest dose increase this method can be used to conduct clinical studies.
منابع مشابه
Measurement of absorbed dose in normoxic polymer gel and study of gold nanoparticles configuration effects
Radiotherapy includes all methods that can deliver a particular amount of ionizing radiation to malignant tissues, assuming that minimal damage hurts healthy tissues. We are looking for a valuable and reliable method to measure absorbed dose and the ability to measure the distribution of absorbed dose in three dimensions which nowadays is one of the three-dimensional dosimetry methods in using ...
متن کاملThe Impact of Nano-Sized Gold Particles on the Target Dose Enhancement Based on Photon Beams Using by Monte Carlo Method
Objective(s): In this study we evaluate the impact of the different aspects of Gold Nano-Particles (GNPs) on the target absorptive Dose Enhancement Factor (DEF) during external targeted radiotherapy with photon beams ranging from kilovolt to megavolt energies using Monte Carlo simulation. Methods: We have simulated the interaction of photon beams wi...
متن کاملEvaluation of the Effects of Inhomogeneities on Dose Profiles Using Polymer Gel Dosimeter and Monte Carlo Simulation in Gamma Knife
Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...
متن کاملDose enhancement effect of gold nanoparticles on MAGICA polymer gel in mega voltage radiation therapy
Background: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like developed to date. Among the special features of this type of dosimeters, is be doped with other elements or chemicals which made them appropriate for investigating of dose enhancement with contrast agents, by high atomic number. Material and Methods: In this study...
متن کاملEvaluation of glandular dose in mammography in the presence of breast cyst using Monte Carlo simulation
Introduction: Average glandular dose (AGD), entrance skin air kerma (ESAK) and normalized glandular dose (DgN) are the main dosimetric quantities in mammography. In this study, DgN is evaluated in the presence of breast cyst, which is a common disease among women and the influence of size, number and location of the cysts on the DgN is investigated. Materials and Meth...
متن کاملthe impact of nano-sized gold particles on the target dose enhancement based on photon beams using by monte carlo method
objective(s): in this study we evaluate the impact of the different aspects of gold nano-particles (gnps) on the target absorptive dose enhancement factor (def) during external targeted radiotherapy with photon beams ranging from kilovolt to megavolt energies using monte carlo simulation. methods: we have simulated the interaction of photon beams with various energies of radiation using water s...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 15 شماره Special Issue-12th. Iranian Congress of Medical Physics
صفحات 86- 86
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023