In vivo dose verification using using an amorphous silicon flat panel-type imager (a-Si EPIDs)
نویسندگان
چکیده مقاله:
Introduction: Electronic portal imaging devices (EPIDs) could be used to dose verification of radiotherapy treatment plans. In vivo dose verification is performed to reduce differences found between dose delivered to the patient and the prescribed dose. The aim of this study was to perform a fast and efficient technique for the verification of delivered dose to the patient using an a-Si EPID. To this end, the transit dose was measured using the EPID. Then, back projection of the portal dose images obtained during the treatment was performed to reconstruct the in vivo dose. Materials and Methods: This study was performed using an amorphous silicon flat panel- type imager (a-Si EPIDs) (Elekta iViewGT) on an Elekta linear accelerator. EPID transit images were acquired for different high-energy open photon beams (i.e., 6, 10, and 15 MV). Then, the following procedure was used to derive the parameters of a formalism to reconstruct the dose in a single plane, intersecting the isocenter, perpendicular to the beam axis and parallel with the EPID detector plane. The formalism is based on the conversion of the aSi EPID response to dose at the maximum depth in water. Moreover, the doses at the maximum depth in the absence of phantom as well as dose in the phantom at the point of interest are obtained by using the transit Tissue Maximum Ratio (TMR). The ionization chamber located at the center of the EPID plane was used to measure the dose. Then, a comparison between the central axis doses of the EPID signal and ionization chamber measurements was performed. In order to check the clinical implementation of the technique as well as the verification of patient plans, the protocol has been performed on 10 patients with prostate cancer treated with three dimensional conformal beams. For every patient, EPID images acquisition and measurement were made during the radiotherapy for seven successive fractions. Results: The deviation between the ionization chamber and EPID signals in this study was in acceptable range (1 SD) which is consistent with the tolerance of the established studies. Furthermore, ratios between the prescribed dose planned by TPS and reconstructed dose from EPID measurements agreed well (mean±SD: 0.995±0.033). Conclusion: our study showed that the aSi EPID can be used as a transit dosimeter. Furthermore, the applied method to reconstruct the dose delivered in the patient is straightforward, reproducible, and rapid for repeated in vivo dose verification.
منابع مشابه
Amorphous Silicon Flat Panel Imagers for Medical Application
A new gamma camera based on hydrogenated amorphous silicon (a-Si:H) pixel arrays to be used in nuclear medicine is introduced. Various performance characteristics of a-Si:H imagers are reviewed and compared with those of currently used equipment. An important component in the a-Si:H imager is the scintillator screen. A new approach for fabrication of high resolution CsI(Tl) scintillator layers,...
متن کاملA-Si FLAT PANEL
Flat Panel Illustration In 2000, a large array A-Si flat panel EPID detector was installed (AL-7) on one of the PRIMUS accelerator at UCSF to allow for a comparison of performance. During the development period of MVCBCT, the introduction in 2004 of a new flat panel (AG-9) better optimized for high energy photons showed a several fold increase in sensitivity, allowing the routine acquisition of...
متن کاملImage quality and radiation dose on digital chest imaging: comparison of amorphous silicon and amorphous selenium flat-panel systems.
OBJECTIVE The aim of this study was to compare the image quality and radiation dose in chest imaging using an amorphous silicon flat-panel detector system and an amorphous selenium flat-panel detector system. In addition, the low-contrast performance of both systems with standard and low radiation doses was compared. MATERIALS AND METHODS In two groups of 100 patients each, digital chest radi...
متن کاملHigh-energy and thermal-neutron imaging and modeling with an amorphous silicon flat-panel detector.
The Los Alamos Neutron Science Center (LANSCE) operates two spallation neutron sources dedicated to research in materials science, condensed-matter physics, and fundamental and applied nuclear physics. Prior to 1995, all thermal neutron radiography at Los Alamos was done on a beam port attached to the Omega West reactor, a small 8MW research reactor used primarily for radioisotope production an...
متن کاملRunning head: COMPARISON OF AMORPHOUS SELENIUM AND AMORPHOUS 1 Comparison of Amorphous Selenium and Amorphous Silicon Flat-Panel Detectors
Digital radiographic flat-panel detectors may operate with direct or indirect manners of converting x-ray photon energy into spatial energy signals. Advances in both technologies have led to radiographic work areas that are faster and lend toward lower patient radiation doses. Superior image quality with an abundance of post-processing capabilities is a benefit as well. Whether based on amorpho...
متن کاملLow‐dose 2.5 MV cone‐beam computed tomography with thick CsI flat‐panel imager
Most of the treatment units, both new and old models, are equipped with a megavoltage portal imager but its use for volumetric imaging is limited. This is mainly due to the poor image quality produced by the high-energy treatment beam (> 6MV). A linac at our center is equipped with a prototype 2.5 MV imaging beam. This study evaluates the feasibility of low-dose megavoltage cone-beam imaging wi...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 15 شماره Special Issue-12th. Iranian Congress of Medical Physics
صفحات 452- 452
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023