In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination
نویسندگان
چکیده مقاله:
In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag reflex, pregnancy or superimposition of anatomical structures on root canal may be considered as some of the limitations to this procedure. Therefore, application of any accessory measurement device may be useful. The aim of this investigation was to assess the ability of two apex locator systems (Ipex and Raypex5) in measuring root canal length accurately. Materials & Methods: A total of 160 extracted human teeth were used in this laboratory investigation. The teeth were divided into 3 groups of single-canal, two-canal and three-canal teeth. The access cavities were then prepared and the actual length of each canal was measured by inserting an appropriate file into the canal until the tip of the file was seen at the apical foramen. The Donnelly test medium was prepared and each tooth was placed in the medium up to the CEJ. The length of each tooth was measured again and recorded using Ipex and Raypex5 systems. The data were statistically analyzed using Liner-Regression, McNemar and t-tests. Results: The accuracy of Raypex5 showed to be 83.1% (95% CI: 77.3-89). Likewise the accuracy of Ipex was 78.8% (95% CI: 72.3-85.2). Both measurements were with in the limits of ±0.5mm from apical foramen. Mc Nemar test showed no significant difference between the two groups (P=0.337). Conclusion: Based on the results of this study, it can be concluded that manufacturers' data are not always reliable. However, these systems can be used as accessories in addition to radiography for accurate working length measurements. Key words: Working length - Electronic apex locator - Raypex5 - Ipex. Corresponding Author: Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. e.mail: [email protected]
منابع مشابه
Ex vivo evaluation of the accuracy of two electronic apex locators during root canal length determination in primary teeth.
AIM To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. METHODOLOGY One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the ac...
متن کاملAccuracy of Working Length Determination using NovApex and Root-ZX Apex Locators: An in vitro Study.
INTRODUCTION This ex vivo study evaluated the accuracy of the Root-ZX electronic apex locator (EAL) (J. Morita, Tokyo, Japan) and the NovApex (Forum Technologies, Rishon Lezion, Israel) in determining the working length (WL) during endodontic treatment. MATERIALS AND METHODS Forty extracted single-rooted human teeth were selected for this study. The actual WL was measured with visual techniqu...
متن کاملevaluation of the in vitro accuracy of an electronic apex locator in measuring resorbed root canal length in primary teeth
0
متن کاملIn vitro evaluation of the accuracy of two electronic apex locators
This study involves evaluating the accuracy of two electronic apex locators (EALs), Raypex and Neosono Co-pilot. Ten single-root human anterior teeth were used for the study. The crown was sectioned to gain access to the root canal. For each tooth, the reference (or control) length, corresponding to the actual length, was determined, after which all the teeth were measured independently. The re...
متن کاملComparative evaluation of the accuracy of two electronic apex locators in determining the working length in teeth with simulated apical root resorption: An in vitro study
INTRODUCTION Accurate determination of working length (WL) is a critical factor for endodontic success. This is commonly achieved using an apex locator which is influenced by the presence or absence of the apical constriction. Hence, this study was done to compare the accuracy of two generations of apex locators in teeth with simulated apical root resorption. MATERIALS AND METHODS Forty maxil...
متن کاملin vitro comparison of working length determination using three different electronic apex locators
background: the aim of this study was to compare the accuracy of the apex-locating functions of dentaport zx, raypex 5 and endo master electronic apex locators (eals) in vitro. materials and methods: thirty extracted human single-rooted teeth with mature apices were used for the study. the real working length (rwl) was established by subtracting 0.5 mm from the actual root canal length. all tee...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 19 شماره 4
صفحات 84- 90
تاریخ انتشار 2008-03
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی برای این مقاله ارائه نشده است
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023