Improving the two-wavelength fundus oximetry method for quantitatively measuring retinal oxygen saturation in eye model phantom using a steady state diffusion algorithm
نویسندگان
چکیده مقاله:
این مقاله چکیده ندارد
منابع مشابه
Algorithms for automated oximetry along the retinal vascular tree from dual-wavelength fundus images.
We present an automated method to perform accurate, rapid, and objective measurement of the blood oxygen saturation over each segment of the retinal vascular hierarchy from dual-wavelength fundus images. Its speed and automation (2 s per entire image versus 20 s per segment for manual methods) enables detailed level-by-level measurements over wider areas. An automated tracing algorithm is used ...
متن کاملA Microcolorimetric Method for Measuring the Oxygen Saturation of Blood
For purposes of measuring oxygen saturation in the arterial blood of newly born infants (1) it became necessary to develop a rapid and reasonably accurate method for small blood samples. It was further necessary to demonstrate that cutaneous blood samples could be considered identical with specimens drawn directly from an artery. The present communication describes the calorimetric method evolv...
متن کاملValidation of human whole blood oximetry, using a hyperspectral fundus camera with a model eye.
PURPOSE To assess the accuracy of human blood oximetry measurements in a model eye with a hyperspectral fundus camera. METHODS Seven human whole blood samples (two arterial, five venous) were obtained, the oxygen saturations measured with a CO oximeter, and the samples inserted into quartz tubes with internal diameters of 100 and 150 μm. The tubes (n = 20; ten 100 μm and ten 150 μm) were plac...
متن کاملA tri state mechanism for oxygen release in fish hemoglobin: Using Barbus sharpeyi as a model
Hemoglobin is a porphyrin containing protein with an a2b2 tetrameric structure and like other porphyrin compounds shows spectral behavior of species specific characteristics. Researchers tend to relate bands in the hemoglobin spectra to certain structural and/or functional features. Given the fact that hemoglobin is the main oxygen carrier in animals functioning through the Oxy«Deoxy equilibriu...
متن کاملPulse Oximetry Overestimates Oxygen Saturation in COPD.
BACKGROUND Measurement of oxygen saturation with a handheld pulse oximeter is widely practiced as a surrogate to invasive arterial blood gas analysis. Oxygen saturation is an important parameter in cases of COPD, but there are insufficient data on the role of pulse oximetry in patients with COPD, moreso in diseases across its spectrum, such as chronic bronchitis and emphysema. We assessed the p...
متن کاملAn oxygen consuming phantom for simulating oxygen perfusion in tissue using F MRI oximetry
Introduction Tumor hypoxia is well known to reduce cancer treatment efficacy [1]. Hypoxic tumor cells, which have decreased oxygen levels (pO2), are more resistant to radiotherapy and chemotherapy. Dissolved oxygen influences the F magnetic resonance relaxation times of perfluorocarbons [2]. This property has been used in animal studies to image tumor oxygenation [3]. However, validation of pO2...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 16 شماره 1
صفحات 10- 2
تاریخ انتشار 2019-05
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی برای این مقاله ارائه نشده است
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023