Improvement of diagnostic accuracy of Parkinson's disease on I-123-ioflupane single photon emission computed tomography (123I FP-CIT SPECT) using new Japanese normal database
نویسندگان
چکیده مقاله:
Objective(s): I-123-ioflupane single photon emission computed tomography (FP-CIT-SPECT) has been used to assess dopamine transporter (DAT) loss in Parkinson's disease. The specific binding ratio (SBR), a quantitative parameter of DAT density in the striatum, may be affected by differences in age, sex, and SPECT system. The purpose of this study was to evaluate the utility of FP-CIT-SPECT using the Japanese normal database (NDB) in the diagnosis of Parkinson's disease. Methods: To standardize the quantitative outcome measures of DAT density obtained with different SPECT systems, striatal phantoms filled with striatal to background materials at ratios between 8:1 and 1:1 were measured using a gamma camera (ECAM) in our institute. Consecutive fifty patients (23 men and 27 women; age range, 40-86 years) with suspected PD undergoing FP-CIT SPECT brain imaging during the period from April to October 2016 were enrolled in this retrospective study. Their final diagnoses were PD in 28 patients and PD in 22 patients. SBRs of the patients were calculated using either new (Japanese database with different age and sex; NEWver) or old (non-Japanese database not specifying age and sex; OLDver) version software (AZE Virtual Place Hayabusa [DaTView], AZE, Ltd. Tokyo, Japan). The McNemar test was used to compare the diagnostic accuracy between old and new versions. Results: Based on the phantom study, the calibrated SBR could be calculated by Y=1.25×Measured SBR+0.78. The sensitivities for OLDver and NEWver were 100% and 93%, respectively (p=0.5), and the specificities were 55% and 100% (p=0.002). The diagnostic accuracy of NEWver (96%) was better than that of OLDver (80%, p<0.001). Conclusion: FP-CIT-SPECT using the Japanese NDB improved the diagnostic accuracy of PD by improving specificity.
منابع مشابه
Diagnostic accuracy of 123 I-FP-CIT SPECT in diagnosing drug-induced parkinsonism: a prospective study.
INTRODUCTION Drug-induced parkinsonism is a major type of parkinsonism in our setting. Symptoms usually disappear after discontinuation of the drug. However, they may persist in patients with a variant known as subclinical drug-exacerbated parkinsonism; early identification of this entity has important prognostic and therapeutic implications. The most widely used complementary test in this diag...
متن کاملDiagnostic accuracy of 123I-FP-CIT SPECT in possible dementia with Lewy bodies.
BACKGROUND (123)I-FP-CIT SPECT (single photon emission computed tomography) can help in the differential diagnosis of probable dementia with Lewy bodies (Lewy body dementia) and Alzheimer's disease. AIMS Our aim was to determine the accuracy of (123)I-FP-CIT SPECT in diagnosing people with possible dementia with Lewy bodies. METHOD We undertook a 12-month follow-up of 325 individuals with p...
متن کاملDiagnostic Accuracy of Parkinson Disease by Support Vector Machine (SVM) Analysis of 123I-FP-CIT Brain SPECT Data
Brain single-photon-emission-computerized tomography (SPECT) with I-ioflupane (I-FP-CIT) is useful to diagnose Parkinson disease (PD). To investigate the diagnostic performance of I-FP-CIT brain SPECT with semiquantitative analysis by Basal Ganglia V2 software (BasGan), we evaluated semiquantitative data of patients with suspect of PD by a support vector machine classifier (SVM), a powerful sup...
متن کاملI]FP-CIT SPECT images
Aim The purpose of the current paper is to present a computational solution to accurately quantify a specific to a non-specific uptake ratio in [ 123 I]FP-CIT single photon emission computed tomography (SPECT) images and simultaneously measure the spatial dimensions of the basal ganglia, commonly known as basal nuclei. A statistical analysis based on a reference dataset selected by the user is ...
متن کاملOptimal ROI setting on the anatomically normalized I-123 FP-CIT images using high-resolution SPECT
OBJECTIVE The aim of this study is to establish the optimal regions of interest (ROIs) in anatomically normalized I-123 FP-CIT SPECT images for the quantification of dopamine transporter binding. METHODS The subjects comprised 16 normal controls and 14 Parkinsonian patients. All of the normal control subjects underwent I-123 FP-CIT SPECT and MRI. The SPECT device used in this study was a Tosh...
متن کاملAlpha4beta2 nicotinic receptor status in Alzheimer's disease using 123I-5IA-85380 single-photon-emission computed tomography.
BACKGROUND Loss of the alpha4beta2 nicotinic receptor subtype is found at autopsy in Alzheimer's disease. OBJECTIVE To investigate in vivo changes in this receptor using single-photon-emission CT (SPECT) with 123I-5-iodo-3-[2(S)-2-azetidinylmethoxy] pyridine (5IA-85380), a novel nicotinic acetylcholine receptor ligand which binds predominantly to the alpha4beta2 receptor. METHODS 32 non-smo...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 8 شماره 2
صفحات 95- 101
تاریخ انتشار 2020-07-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023