High Performance Liquid Chromatography Determination of Sertraline in Human

نویسندگان

  • Amir Farshchi School of Pharmacy, Kermanshah University of Medical Sciences, Kermanshah, Iran Department of Pharmocoeconomy and Pharmaceutical Management, Shcool of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
  • Gholamreza Bahrami School of Pharmacy, Kermanshah University of Medical Sciences, Kermanshah, Iran
  • Golbarg Ghiasi School of Pharmacy, Kermanshah University of Medical Sciences, Kermanshah, Iran Department of Pharmocoeconomy and Pharmaceutical Management, Shcool of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
چکیده مقاله:

       An accurate and sensitive reversed-phase high-performance liquid chromatograph-ic method for determination of sertraline in human serum is described using 4-chloro-7-nitrobenzofurazan as pre-column derivatization agent. The drug and an internal standard (azithrimycin) were extracted from serum using a mixture of diethyl ether-chloroform and subjected to the pre-column derivatization with the reagent. Analysis of the resulted derivatives was performed on a Lichrosorb CN (250×4.0 mm) column using a mobile phase composed of methanol and sodium phosphate buffer (0.05 M; pH 3.7) containing 2 ml/lit triethylamine (63:37 v/v). Detector response was monitored at excitation and emission wavelengths of 470 and 537 nm, respectively. The calibration curve was linear over the concentration range of 2 to 640 ng/ml. The lower limits of detection and quantification were 0.5 and 2 ng/ml, respectively. The validation of the analysis was carried out in terms of specificity, sensitivity, linearity, precision, accuracy and stability. The validated method was shown to be accurate, with intra-day and inter-day accuracy from 0.3 to 4.2% and precise, with intra-day and inter-day precision from 2.4 to 15.5%. The drug is detected at concentrations as low as 2 ng/ml in a 0.5 ml serum sample and the described method can be easily applied in human single-dose pharmacokinetic studies of sertraline.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

high performance liquid chromatography determination of sertraline in human

an accurate and sensitive reversed-phase high-performance liquid chromatograph-ic method for determination of sertraline in human serum is described using 4-chloro-7-nitrobenzofurazan as pre-column derivatization agent. the drug and an internal standard (azithrimycin) were extracted from serum using a mixture of diethyl ether-chloroform and subjected to the pre-column derivatization with the re...

متن کامل

High-Performance Liquid Chromatography Determination of Methotrexate in Plasma

This article describes a simple and fast high-performance liquid chromatography method for the determination of methotrexate (MTX) in plasma. Samples were collocted from children receiving high-dose MTX at shafa Hospital (Ahvaz University of Medical sciences, Ahvaz, iran) at various times after the end of eachinfusion. Plasma was deproteinized with trichloroacetic acid and the supernatant was i...

متن کامل

High-Performance Liquid Chromatography Determination of Methotrexate in Plasma

This article describes a simple and fast high-performance liquid chromatography method for the determination of methotrexate (MTX) in plasma. Samples were collocted from children receiving high-dose MTX at shafa Hospital (Ahvaz University of Medical sciences, Ahvaz, iran) at various times after the end of eachinfusion. Plasma was deproteinized with trichloroacetic acid and the supernatant was i...

متن کامل

HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC DETERMINATION OF THEOPHYLLINE IN HUMAN SERUM

A simple, rapid and sensitive HPLC method for the determination of theophylline (T) in human serum has been developed. An isocratic system consisting of a /-l Bondapak C18 column, mobile phase of methanol, phosphate buffer (22:78, pH=4.5), and a flow rate of 1.4 mL/min was used. The eluent was detected by UV at 275 nm at room temperature. 8-Chlorotheophylline (8-CT) was used as an internal ...

متن کامل

Vortex-Assisted Inverted Dispersive Liquid-Liquid Microextraction of Naproxen from Human Plasma and Its Determination by High-Performance Liquid Chromatography

Extraction and determination of naproxen from human plasma were performed using Vortex-Assisted Inverted Dispersive Liquid-Liquid MicroExtraction (VA−IDLLME) and High-Performance Liquid Chromatography (HPLC). The parameters affecting extraction recovery such as type and volume of extraction and disperser solvents, pH of sample solution, stirring rate, extraction time and salt addition were ...

متن کامل

high-performance liquid chromatography determination of methotrexate in plasma

this article describes a simple and fast high-performance liquid chromatography method for the determination of methotrexate (mtx) in plasma. samples were collocted from children receiving high-dose mtx at shafa hospital (ahvaz university of medical sciences, ahvaz, iran) at various times after the end of eachinfusion. plasma was deproteinized with trichloroacetic acid and the supernatant was i...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 5  شماره 3

صفحات  171- 178

تاریخ انتشار 2009-07-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023