HEPA Filters specifications in two standards, ASME AG-1 & DOE for using in Tehran Research Reactor (TRR)

نویسنده

چکیده مقاله:

HEPA filters serve as important safety device to protect personnel as well as the public and environment from the radiation effects exist in the air, so they are vital devices in the event accidents. DOE provides directions through the use of two technical standards, 3020 and 3025, including QA requirements for the procurement, packaging, shipping and storage of HEPA filters and also provides direction to the QA requirements for HEPA filter inspection and testing, which their media is Fiber-glass and designed according to the FC and FK sections of ASME AG-1 code.   The DOE Technical Standards specifically state that inspection and testing are to be performed at an independent FTF prior to filter installation at DOE nuclear facilities and this is in addition to the inspection and testing performed by the filter manufacturers. By applying a four step QA inspection and testing program in DOE FTF, the rate of annually deficiencies in visual inspections is 3-5 percent and for flow inspections is about 2 percent and these values sustained during 40 years of applying this program which shows this program is efficient. Also a good relation between AG-1 and DOE is performed, caused the requirements of AG-1 be revised according to this program. In this paper firstly HEPA filter structure and its different types is described, then DOE program of  QA inspections and testing of filters is discussed, and finally deficiencies of ventilation system of TRR in comparison to this program is mentioned in results.    

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standards for Reporting Qualitative Research

سخن سردبیر Editorial مجله دانشگاه علوم پزشکی رفسنجان دوره هجدهم، آذر 1398، 860-859       استاندارد‌هایی برای گزارش پژوهش‌‌های کیفی Standards for Reporting Qualitative Research     محسن رضائیان[1]   M. Rezaeian   تاکنون در مجله علمی دانشگاه، مقالات گوناگونی در خصوص استاندارد‌های تدوین شده برای گزارش شفاف پژوهش‌های کمّی و از جمله کارآزمایی‌‌های بالینی [1] و مطالعات مشاهده‌ای اپیدمیو...

متن کامل

Calculation and evaluation of the vital head organs dose during Neutron Therapy in Tehran Research Reactor using Zubal phantom

In the recent years some studies has been done to consider the capability of Tehran Research Reactor for Boron neutron capture therapy (BNCT). The purpose of this study is to evaluate the sensitive organs dose during the treatment of patient with deep brain tumor by TRR. The calculation has been carried out using the Monte Carlo code MCNPX for ZUBAL head and neck phantom. The method was tested ...

متن کامل

Flow Blockage Accident Analysis of Tehran Research Reactor Fuel Assembly

Tehran Research Reactor (T.R.R.) is a pool-type, 5 MW thermal research reactor. One probable event is that if some external objects or debris fall down into the reactor core and cause obstruction of the coolant flow through one of the fuel assemblies, decreasing the surface flow area, ceases the coolant flow, and also raises the fuel and sheaths tempe...

متن کامل

synthesis of platinum nanostructures in two phase system

چکیده پلاتین، فلزی نجیب، پایدار و گران قیمت با خاصیت کاتالیزوری زیاد است که کاربرد های صنعتی فراوانی دارد. کمپلکس های پلاتین(ii) به عنوان دارو های ضد سرطان شناخته شدند و در شیمی درمانی بیماران سرطانی کاربرد دارند. خاصیت کاتالیزوری و عملکرد گزینشی پلاتین مستقیماً به اندازه و- شکل ماده ی پلاتینی بستگی دارد. بعضی از نانو ذرات فلزی در سطح مشترک مایع- مایع سنتز شده اند، اما نانو ساختار های پلاتین ب...

shielding and criticality safety analyses for spent fuel transportation cask in tehran research reactor

in this research, shielding and criticality safety calculations carried out for interim storage and transportation cask in the tehran research reactor. such dual purpose cask is being designed to the spent fuel elements of research reactors. the monte carlo mcnp5 code calculation was utilized for the criticality safety analysis and origen2.1code was used for shielding calculation. according to ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 8  شماره 4

صفحات  403- 410

تاریخ انتشار 2020-08

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023