Introduction: Treatment with megavoltage electron beams is ideal for irradiating superficial tumors because of their limited range in tissues. However, for electron treatment of extended areas, such as the chest wall, two or more adjacent fields can be used. Abutment of these fields may lead to significant dose in homogeneities in the junction region. The aim of this study is to offer a new method for generating a homogeneous dose distribution in the junction region between two adjacent fields in electron beam therapy. Materials and Methods: Several approaches have been proposed to solve the problem of ‘hot’ and ‘cold’ spots in the junction region between abutting electron fields. These techniques are based on beam-edge modifying devices or penumbra generators which act to broaden the electron beam penumbra, and thus facilitate field matching. But use of these devices is time consuming and design of the modifications to the applicators are generally applicator dependent. An idea which was originally proposed for matching two adjacent photon fields (with dose inhomogeneity of about 2%) is resurrected here. This method is based on the rotation of the gantry such that the adjacent fields have a common edge and the overlap region in treatment volume is eliminated. For this purpose, the effective source to surface distance (SSDeff) for the available electron beam energies (6, 9, 12 and 15 MeV) and applicators (cones) (6 × 6, 10 × 10, 15 ×15, 20 × 20 and 25 × 25 cm2) have been determined for a Varian 2100C linear accelerator. Result: Using SSDeff, in respect to beam divergence, one can use the photon beam behavior for electron beams and achieve a uniform dose distribution in adjacent electron fields. Discussion and Conclusion: Compared to beam-edge modifying devices or penumbra generators that are usually time consuming to plan and set up, rotating the gantry to eliminate the overlap region is simple and applicable in the problem of abutting electron fields.
منابع مشابه
A new method for ideal dose distribution of two adjacent fields for external beam radiation therapy
Abstract Background: Adjacent treatment fields are commonly used in external beam radiation therapy, such as mantle and inverted-Y fields for the treatment of Hodgkin’s disease and craniospinal fields used in the treatment of medulloblastoma and head and neck tumors when the lateral neck fields are placed adjacent to the anterior supraclavicular field. In each of these situations, there is a p...
متن کاملa new method for ideal dose distribution of two adjacent fields for external beam radiation therapy
abstract background: adjacent treatment fields are commonly used in external beam radiation therapy, such as mantle and inverted-y fields for the treatment of hodgkin’s disease and craniospinal fields used in the treatment of medulloblastoma and head and neck tumors when the lateral neck fields are placed adjacent to the anterior supraclavicular field. in each of these situations, there is a po...
متن کاملA new method for ideal dose distribution of two adjacent fields for external beam radiation therapy
Background: Adjacent treatment fields are commonly used in external beam radiation therapy, such as mantle and inverted-Y fields for the treatment of Hodgkin’s disease and craniospinal fields used in the treatment of medulloblastoma and head and neck tumors when the lateral neck fields are placed adjacent to the anterior supraclavicular field. In each of these situations, there is a possibility...
متن کاملa cross-comparative dtudy between two textbook series in terms of the presentation of politeness
چکیده ندارد.
15 صفحه اولElectron Beam Dose Distribution in the Presence of Non-Uniform Magnetic Field
Introduction Magnetic fields are capable of altering the trajectory of electron beams andcan be used in radiation therapy.Theaim of this study was to produce regions with dose enhancement and reduction in the medium. Materials and Methods The NdFeB permanent magnets were arranged on the electron applicator in several configurations. Then, after the passage of the electron beams (9 and 15 MeV Va...
متن کاملEffect of Tissue Composition on Dose Distribution in Electron Beam Radiotherapy
Objective: The aim of this study is to evaluate the effect of tissue composition on dose distribution in electron beam radiotherapy.Methods: A Siemens Primus linear accelerator and a phantom were simulated using MCNPX Monte Carlo code. In a homogeneous cylindrical phantom, six types of soft tissue and three types of tissue-equivalent materials were investigated. The tissues included muscle (ske...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 7 شماره 3
صفحات 29- 34
تاریخ انتشار 2010-09-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023