Functional Results of Unstable (Type 2) Distal Clavicle Fractures Treated with Superior Anterior Locking Plate
نویسندگان
چکیده مقاله:
Background: The treatment of distal clavicle fracture is always a challenge, as it is mostly unstable and has higherrate of delayed union, malunion, non-union and associated acromioclavicular arthritis. So the management of thesefractures remains controversial. The purpose of this study is to evaluate the functional results of Type 2 distal endclavicle fractures treated with superior anterior locking plate.Methods: From June 2011 to August 2015 a retrospective study of12 male patients (mean age of 41.3 years) 11 withunilateral and 1 with bilateral distal clavicle fractures treated with superior anterior locking plate was done. They wereevaluated at regular intervals with mean follow up of 14 months(12-18 months).Those with minimum one year followup were included in our study. All were evaluated for the functioning of the shoulder joint by both Oxford shoulder scoreand Quick DASH scores, rate of bone union, complications and earliest time for return to work.Results: All fractures union seen within 6-8 weeks (mean time: 7.1 weeks).All had good shoulder range of motion. Theaverage oxford shoulder and Quick DASH score were 46.2 and 6.5.There were no major complications in our studyviz. non-union, plate failure, secondary fracture. But one patient had superficial wound infection. All patients returned towork within 3 months of postoperative period.Conclusion: Displaced distal clavicle fractures treated with superior anterior locking plates achieved excellent resultsin terms of bony union with rarely any complications and demonstrate promising results with this novel technique.
منابع مشابه
Functional Results of Unstable (Type 2) Distal Clavicle Fractures Treated with Superior Anterior Locking Plate.
Background The treatment of distal clavicle fracture is always a challenge, as it is mostly unstable and has higher rate of delayed union, malunion, non-union and associated acromioclavicular arthritis. So the management of these fractures remains controversial. The purpose of this study is to evaluate the functional results of Type 2 distal end clavicle fractures treated with superior anterior...
متن کاملFixation of unstable type II clavicle fractures with distal clavicle plate and suture button.
This article reports on a technique to treat unstable type II distal clavicle fractures using fracture-specific plates and coracoclavicular augmentation with a suture button. Six patients with clinically unstable type II distal clavicle fractures underwent treatment using the above technique. All fractures demonstrated radiographic union at 9.6 (8.4-11.6) weeks with a mean follow-up of 15.6 (12...
متن کاملOutcome of distal end clavicle fractures treated with locking plates
PURPOSE Fractures of the lateral end of the clavicle are relatively uncommon. These fractures are unstable due to the various deforming forces which act on the fragments as well as the small distal fracture fragment. At most times the deforming forces are not taken into consideration, and the fracture is not fixed securely. In this study, we assessed a fixation technique using the precontoured ...
متن کاملThe Osteosynthesis of Unstable Fractures of the Distal Clavicle with Hook Plate
This open-access article is published and distributed under the Creative Commons Attribution NonCommercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article witho...
متن کاملPrecontoured Locking Plate Treatment in Mid-Shaft Clavicle Fractures: Outcomes and Complications with a Minimun of 2- Years Follow up
Background: The aim of this study was to evaluate functional outcome and complications with a long term followup (minimum of 2 years post-operative) in patients with mid-shaft clavicle fractures treated with precontoured lockingplates.Methods: We included 41 patients. Goniometric measurement of shoulder range of motion (ROM) was performed,as well as functional evaluation using the rating scale ...
متن کاملFunctional outcome of distal femoral fractures treated by minimally invasive surgery using locking condylar plate
Correspondence should be sent to: [email protected] ABSTRACT Background: The management of distal femoral fractures has presented significant challenge to Orthopaedic surgeons. A wide medullary canal, thin cortex and poor bone stock make stable internal fixation in these fractures difficult. Severe soft tissue damage, extensive comminution, intrarticular extension and injury to quadriceps mecha...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 5 شماره 6
صفحات 394- 399
تاریخ انتشار 2017-11-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023