Flexural Performance of High-strength Prestressed Concrete-encased Concrete-filled Steel Tube Sections
نویسندگان
چکیده مقاله:
The sections composed of concrete and steel, which include concrete-encased concrete-filled tubes, generally have defects due to the low tensile strength of concrete. Therefore, an appropriate method was used for the combination of concrete-filled tubes (CFT) and prestressing strands which is encased in concrete. The conventional design guidelines are commonly developed for materials with normal strength thus further investigation is required to be conducted for sections with high-strength materials. In order to develop the design process, high-strength concrete and steel have been utilized in this study to examine the effects of steel and concrete strengths on the core concrete confinement, sectional size and flexural behavior of high-strength prestressed concrete-encased CFST (HS-PCE-CFST) beams. Hence, a total of thirteen HS-PCE-CFST beams were modeled via ABAQUS finite element software. The main variables include the steel tube yield strength, compressive cylinder strength of the core and outer concrete and the steel tube diameter to section width ratio. Furthermore, experimental results were employed to verify the finite element model. The bending moment, ductility, flexural stiffness and failure mode of beams are also examined. The results confirm that among the compressive strength of the outer and core concrete and the steel tube yield strength, change in the outer concrete compressive strength has a greater effect on the change of flexural parameters, also increasing the ratio of steel tube diameter to section width causes a minor increase in the ultimate bending moment and serviceability level flexural stiffness, but a major escalation in the initial flexural stiffness.
منابع مشابه
Effect of the Concrete Strength on the Concrete-Steel Bond in Concrete Filled Steel Tubes
In this study, the concrete-steel bond strength of concrete filled cylindrical steel tubes has been experimentally investigated. 22 short, high strength and normal concrete filled circular steel tubes were tested. Push-out test was carried out as the common method to evaluate the bond carrying capacity. Four different concrete mixes were used in preparing the specimens. The steel tubes were w...
متن کاملEvaluation and Modifications of the AASHTO Procedures for Flexural Strength of Prestressed Concrete Flanged Sections
Different interpretations of the equivalent rectangular stress block approximation used by the American Association of State Highway and Transportation Officials (AASHTO) Load and Resistance Factor Design (LRFD) and AASHTO Standard Specifications may lead to inconsistencies in the sectional response of the prestressed concrete flanged sections predicted by the two specifications. According to t...
متن کاملDuctility of Prestressed and Partially Prestressed Concrete Beam Sections
D analyses of structures responding elastically to ground motions recorded during severe earthquakes have shown that the theoretical response inertia loads are generally significantly greater than the static design lateral loads recommended by codes. Hence, structures designed for the lateral earthquake loads recommended by codes can only survive severe earthquakes if they have sufficient ducti...
متن کاملBehavior of FRP-Confined Concrete-Filled Steel Tube Columns
This paper presents the results of an experimental study into the behavior of concrete-filled steel tube columns confined by fiber-reinforced polymer (FRP). Eleven columns were tested to investigate the effects of the FRP layer number, the thickness of the steel tube and concrete strength on their load capacity and axial deformation capacity. The experimental results indicated that the FRP wrap...
متن کاملNumerical Simulation of Ultra- Strength Concrete-filled Steel Columns
Article history: Received: 11. 09. 2013. Received in revised form: 01. 10. 2013. Accepted: 15. 10. 2013. Researches into the constitutive relation of the super high strength and high performance concrete and the stress strain relationship of the ultrastrength concrete-filled steel columns are rare. Therefore, this paper based on continuous mechanics presents the relationship of mathematical des...
متن کاملCyclic Evolution of Damage and Beam-column Interaction Strength of Concrete-filled Steel Tube Beam-columns
The assessment of response of composite seismic force resisting systems requires accurate nonlinear formulations for the composite members. In this work, reporting the first phase of a NEES project, a three-dimensional distributed plasticity formulation is presented for both circular and rectangular composite concrete-filled steel tubes (CFTs) that includes new constitutive models for the concr...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 32 شماره 9
صفحات 1238- 1247
تاریخ انتشار 2019-09-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023