Feasibility of using statistical tests in evaluation of non-uniformity [Persian]

نویسندگان

  • Ahmad Bitarafan Rajabi Department of Medical Physics, School of Medical Sciences, Tarbiat Modarres University, Tehran, Iran
  • Ebrahim Hajizadeh Department of Medical Statistics, Tarbiat Modarres University, Tehran, Iran
  • Fereidoon Rastgoo Nuclear Medicine Department, Shahid Rajaie Heart Hospital, Iran University of Medical Sciences, Tehran, Iran
  • Hassan Firoozabadi Nuclear Medicine Department, Shahid Rajaie Heart Hospital, Iran University of Medical Sciences, Tehran, Iran
  • Hossein Rajabi Department of Medical Physics, School of Medical Sciences, Tarbiat Modarres University, Tehran, Iran
  • Nahid Yaghoobi Nuclear Medicine Department, Shahid Rajaie Heart Hospital, Iran University of Medical Sciences, Tehran, Iran
  • Samira Rasaneh Department of Medical Physics, School of Medical Sciences, Tarbiat Modarres University, Tehran, Iran
چکیده مقاله:

Introduction: Non-uniformity test is essentially the only required daily QC procedure in nuclear medicine practice. Noise creates statistical variation or random error in a flood image. Non-uniformity on the other hand does not have statistical nature and may be regarded as systemic error. The present methods of non-uniformity calculation do not distinguish between these two types of error. The Jarque-Bera and Kolmogorov-Smirnov tests were examined as alternative methods in calculation of non-uniformity in flood test images. Methods: Using the Monte carol method, uniform and non-uniform flood images of different matrix sizes and count density were generated. The uniformity of the images was calculated using the present and proposed methods. The results were also tested using 1300 planar images of 128x128 matrix size. Results: The proposed methods were more accurate and sensitive to non-uniformity at low count density. However, their precisions were less than the conventional methods. There were no significant differences between these procedures at high count density. Conclusion: The integral and differential uniformity do not distinguish between noise always present in the data or in occasional non-uniformity. In a uniform intact flood image, the difference between maximum and minimum pixel count (the value of integral uniformity) is much more than recommended values for non-uniformity. After filtration of image this difference decreases but still remains high. The proposed methods are more sensitive to non-uniformity at low count density and may be used as alternative methods in daily uniformity test.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

feasibility of using statistical tests in evaluation of non-uniformity [persian]

introduction: non-uniformity test is essentially the only required daily qc procedure in nuclear medicine practice. noise creates statistical variation or random error in a flood image. non-uniformity on the other hand does not have statistical nature and may be regarded as systemic error. the present methods of non-uniformity calculation do not distinguish between these two types of error. the...

متن کامل

the washback effect of discretepoint vs. integrative tests on the retention of content in knowledge tests

در این پایان نامه تاثیر دو نوع تست جزیی نگر و کلی نگر بر به یادسپاری محتوا ارزیابی شده که نتایج نشان دهندهکارایی تستهای کلی نگر بیشتر از سایر آزمونها است

15 صفحه اول

evaluation of sadr eminence in safavid period

چکیده: یکی از دوره های مهم تاریخی ایران به لحاظ تأمین استقلال ملی مذهبی و حتی تأثیر آن بر فرهنگ و مذهب ایرانیان، دوره صفویه است. رسمیت دادن و رواج مذهب شیعه توسط شاه اسماعیل اول، یکی از مهمترین اقدامات این دولت محسوب می شود. بنابراین برای اجرای این سیاست، وی منصب صدارت را به عنوان منصبی مذهبی- حکو متی ایجاد کرد .این منصب از دوره ی تیموریان ایجاد شده بود ولی در اواخر این دوره اهمیت بیشتری یافت...

15 صفحه اول

hazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures

شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 13  شماره 2

صفحات  15- 24

تاریخ انتشار 2005-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023