Feasibility of using Medical Imaging Interaction Toolkit in volumetric studies to accurate diagnosing of vascular emboli by Extended NURBS-based Cardiac-Torso phantom

نویسندگان

  • Jalil Pirayesh Islamian Associate Prof., Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran.
  • Mahnaz Amini Assistant Prof., Lung disease research center, Faculty of Medicine Mashhad university of Medicine Sciences, Mashhad, Iran.
  • Masoud Pezeshkirad Assistant Prof., Department of Radiology, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Negar Moro vatdar Assistant Prof., of Community Medicine Imam Reza Clinical Research Units, Faculty of Medicine Mashhad University of Medical Sciences, Mashhad, Iran.
  • SeiedehFatemeh Ayatifard Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
چکیده مقاله:

Introduction: Important complications of venous thromboembolism (VTE) are a longer hospital stay, readmission, recurrence of the emboli, complications of anticoagulant therapy and death in a sever condition. In present study, the volume measurement accuracy of the medical imaging interaction toolkit (MITK) software on determining VTE in computed tomography images was evaluated. Methods: Several VTEs, ranged from 0.1 to 20 mm, were simulated in the arteries of a XCAT Phantom. Then, the MITK software was used for localization and volume measurement of the produced VTEs on the images of the simulated phantom. Results: The scatter plot and correlation coefficient were showed a high correlation between the calculated emboli volume measures by MITK software with those designed in the XCAT Phantom (r=0.98; p<0.001), The differences of the calculated measures and the simulated clots were mostly related to the clot volumes less than 0.1 ml (mainly due to the inability of the software to measure the range), which may be clinically ignored. However, a difference of about 0.01 ml for the clot volumes greater than 0.1 ml was in acceptable range. Conclusion: MITK software may be used for volume measurement studies in medical diagnosis, also for VTE accurate measurement to achieve a more accurate diagnosis and to eliminate the need to onsite diagnosis by the imaging system due to MITK capability on running in a personal computer.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

comparative dna interaction studies of antiviral drug, zidovudine and its complex using different instrumental methods

هدف از این مطالعه بررسی امکان استفاده از داروهای شناخته شده در درمان سایر بیماریها به عنوان داروهای ضد سرطان است. همچنین با استفاده از این داروها در ساختمان کمپلکس فلز می توان شاخص های دارویی بدست آمده را بررسی نمود. داروی ضد ویروس ایدز(hiv)به نام زیدوودین(azt)انتخاب و.کمپلکس.محلول.در.آب[pt(azt)2]cl2سنتزو به روشهای مختلف فیزیکی و شیمیایی شناسایی گردید. بر هم کنش مقایسه ای این دارو و کمپلکس پلا...

15 صفحه اول

analyzing patterns of classroom interaction in efl classrooms in iran

با به کار گیری روش گفتما ن شنا سی در تحقیق حا ضر گفتا ر میا ن آموزگا را ن و زبا ن آموزا ن در کلا سهای زبا ن انگلیسی در ایرا ن مورد بررسی قرار گرفت. ا هداف تحقیق عبا رت بودند از: الف) شنا سا ئی سا ختارهای ارتبا ط گفتا ری میا ن معلمین و زبا ن آموزا ن ب) بررسی تا ثیر نقش جنسیت دبیرا ن و زبا ن آموزان بر سا ختا رهای ارتبا ط گفتا ری میا ن آنها پ) مشخص کردن اینکه آ یا آموزگاران غا لب بر این ارتبا ط گف...

study of cohesive devices in the textbook of english for the students of apsychology by rastegarpour

this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...

the effectiveness of strategy-based instruction in teaching english as a second or foreign language: a meta-analysis of experimental studies

a large number of single research studies on the effects of strategy-based instruction (sbi) in teaching english as a foreign or second language has been conducted so far. however, the lack of a comprehensive meta-analysis targeting the effectiveness of english language sbi is observed. moreover, the findings of experimental studies regarding the context of the english language, proficiency lev...

The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies

Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...

متن کامل

‏‎suppression of coke formation in thermal cracking by coke inhibitors‎‏

‏‎the main purpose of this research was to:1.develop a coking model for thermal cracking of naphtha.2.study coke inhibition methods using different coke inhibitors.developing a coking model in naphtha cracking reactors requires a suitable model of the thermal cracking reactor based on a reliable kinetic model.to obtain reliable results all these models shall be solved simultaneously.for this pu...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  438- 438

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023