Fabrication of anthropomorphic phantoms for use in total body photon irradiation and total skin electron irradiation studies

نویسندگان

  • Ghazale Geraily PhD of Physical Medicine, Physical Medicine department, Tehran University of Medical Science, Tehran, Iran.
  • Heydar Toolee PhD of Anatomy, Anatomy department, Tehran University of Medical Science, Tehran, Iran.
  • Shaghayegh Fahimi Monzari Student of Physical Medicine, Physical Medicine department, Tehran University of Medical Science, Tehran, Iran.
چکیده مقاله:

Introduction: Total Skin Electron Therapy (TSET) and Total Body Irradiation (TBI) are kinds of treatment which use electron and photon beams to treat special types of cancers. The aim of these techniques are to deliver uniform dose to the entire skin while minimizing delivered dose to organs at risk. To check the homogeneity of dose delivery in TBI and TSET, using a humanoid phantom is necessary. Aim of this study is to manufacture an anatomical model of an adult male included lower limb to evaluate the dose distribution in dosimetry measurements of radiotherapy. In addition, we want to offer a method for low-cost fabrication of an anthropomorphic phantom by tissue substitute material compared to similar commercial phantom. Materials and Methods: To design the phantom, CT scan images of the atomic energy organization RANDO phantom were our reference. Also AutoCAD, Corel and Solid works software were used. This Phantom has five different heterogeneities including air, Plexiglas for Soft tissue substitute, Polytetrafluoroethylene (PTFE) for Bone tissue substitute, Cork for Lung tissue and Polyethylene for designing three organs such as rectum, bladder, and prostate and also has four sections including head and neck, trunk, pelvis and two legs. After construction, the phantom was validated by CT number conformity and relative electron density determination methods (such as from tissue's Linear attenuation coefficients and their CT numbers) compare to standard values. In addition, percentage error of the relative electron density calculated from the linear attenuation coefficient and the CT number were compared. Results: The constructed anthropomorphic male RANDO Phantom consists of 175 layers with 1 cm thickness, 175 cm height and 72 kg weight. validating the constructed phantom by two methods demonstrate good agreement between tissue substitute materials in phantom structure in compare to standard values that suggested from ICRU44. percentage error difference in the relative electron density calculated from the linear attenuation coefficient and the CT number was in a good range between 0 -5.91. In the other hand there is no significant difference between reD obtained from these two methods and real tissue electron density (P-value < 0/05) so it can be concluded that both methods are reliable for phantom validation process. Conclusion: Lower limbs can be a good bench mark for evaluation for patients with skin cancers so design of the whole body phantom with two lower limbs is very necessary. The another advantages of this study is use of high stability material that do not destroy over time. Finally, the constructed phantom in this study is recommended for TBI and TSET.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diode calibration for dose determination in total body irradiation

Background: Total Body Irradiation (TBI) is different from standard radiotherapy in many aspects, so it is not easy to predict the delivered dose to the patient under TBI treatment. Diode dosimetry procedures for surface dose reading can help to define variations of the actually delivered dose from the prescribed one. The aim of this study was to describe the measurements made to calib...

متن کامل

Total skin electron irradiation techniques: a review

Total skin electron irradiation (TSEI) has been employed as one of the methods of mycosis fungoides treatment since the mid-twentieth century. In order to improve the effects and limit the complications following radiotherapy, a number of varieties of the TSEI method, frequently differing in the implementation mode have been developed. The paper provides a systematic review of the different var...

متن کامل

Total body irradiation for myelomatosis.

In the first myeloma trial of the M.R.C. working party on leukaemia in adults the deaths that have occurred can be attributed to unrelated diseases (5%h-for example, cosonary thrombosis, etc.); causes indirectly telated to the tumour (80,for example, pneumonia due to the immune paresis); no obvious response of the tumour to treatment (27/); and finally relapse of the tumour after an initial res...

متن کامل

A technique for pediatric total skin electron irradiation

BACKGROUND Total skin electron irradiation (TSEI) is a special radiotherapy technique which has generally been used for treating adult patients with mycosis fungoides. Recently, two infants presented with leukemia cutis isolated to the skin requiring TSEI. This work discusses the commissioning and quality assurance (QA) methods for implementing a modified Stanford technique using a rotating har...

متن کامل

Rotational total skin electron irradiation with a linear accelerator

The rotational total skin electron irradiation (RTSEI) technique at our institution has undergone several developments over the past few years. Replacement of the formerly used linear accelerator has prompted many modifications to the previous technique. With the current technique, the patient is treated with a single large field while standing on a rotating platform, at a source-to-surface dis...

متن کامل

Total-body irradiation for bone marrow transplantation.

Total-body irradiation (TBI), when given as part of bone marrow transplantation (BMT), works by enhancing immune suppression and by exerting a tumoricidal effect. The modality has been made less toxic because of new approaches to delivering TBI, such as fractionation, and partial organ shielding, Colleen Lawton, MD, professor at the Medical College of Wisconsin, Milwaukee, said at the 1998 Amer...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  309- 309

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023