Experimental values for adjusting an automatic control valve in gas pipeline transportation
نویسندگان
چکیده مقاله:
When a natural gas pipeline ruptures, the adjacent automatic line control valves (ALCVs) should close quickly to prevent leakage or explosion. The differential pressure set point (DPS) at each valve location is the main criteria for value setting in ALCV action. If the DPS is not properly adjusted, the ALCV may mistakenly close or it may not take any action at proper time. This study focused on the DPS values prediction for setting ALCV installed on a gas pipeline with 1mm orifice diameter. The effect of characteristic parameters such as pipeline operational pressure (POP) and pipeline pressure drop rate (ROD) due to rupture or major leak was experimentally investigated on DPS. Twenty-five different conditions with double set of typical mentioned characteristic parameters were chosen. For each condition, the differential pressure (DP) was measured over 180 seconds by analyzing the experimental values. Therefore, 25 maximum DP values (DPSs) were obtained. The DPS increases by increase in ROD or decreasing POP parameters. Because of using nitrogen gas instead of natural gas due to safety reasons, the DPS results can be practically applied by adding a safety factor of 15%. The diagram of DPS with respect to ROD and non-dimensional DPS (DOP) versus non-dimensional ROD (RTP) was provided for different POPs.
منابع مشابه
development and implementation of an optimized control strategy for induction machine in an electric vehicle
in the area of automotive engineering there is a tendency to more electrification of power train. in this work control of an induction machine for the application of electric vehicle is investigated. through the changing operating point of the machine, adapting the rotor magnetization current seems to be useful to increase the machines efficiency. in the literature there are many approaches wh...
15 صفحه اولOptimization of natural gas pipeline transportation using ant colony optimization
In this paper, an Ant Colony Optimization Algorithm (ACO) is proposed for operations of steady flow gas pipeline. The system is composed of compressing stations linked by pipe legs. The decisions variables are chosen to be the operating turbo compressor number and the discharge pressure for each compressing station. The objective function is the power consumed in the system by these stations. U...
متن کاملOptimizing Pipeline Control in Transient Gas Flow
Consider a pipeline with time dependent delivery volumes at various load points. Such a system can be controlled by changing with time the pressure setpoints at stations to manipulate flow and linepack. We present an algorithm that computes an optimum set of time-varying setpoint values (out to a user-specified simulation horizon) simultaneously for all stations. These setpoint values are compu...
متن کاملExperimental Study of the Residual Stresses in Girth Weld of Natural Gas Transmission Pipeline
In order to achieve integrated condition in the girth welding of high pressure natural gas transmission pipelines, the weld zones and its surrounding area should have good mechanical properties. Residual stresses are an important defect especially in the girth welding of the pipeline. In this study, two API X70 steel pipes (with spiral seam weld) of 56 inches outside diameter and 0.780 inch wal...
متن کاملComputational Fluid Dynamics Methods for Gas Pipeline System Control
At the present level of development of long, branched gas transmission networks (GTN), solving the problems of improving safety, efficiency and environmental soundness of operation of industrial pipeline systems calls for the application of methods of numerical simulation. The development of automated devices for technical inspection and process control, and availability of high-performance com...
متن کاملInfluence of Pipeline Operating Pressure on Value Setting of Automatic Control Valves at Different Pressure Drop Rates
When a natural gas pipeline ruptures, the adjacent upstream and downstream automatic control valves (ACV) should close quickly to prevent leakage or explosion. The differential pressure set point (DPS) at each valve location is the main criteria for value setting in ACV actions. If the DPS is not properly adjusted, the ACV may mistakenly close or it may not take any actions at a proper ti...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید