Experimental Study on Using Uniform Tuned Liquid Column Damper for Structural Control of Buildings Resting on Loose Soil

نویسندگان

چکیده مقاله:

In this study, through series of shaking table tests and statistical analysis, the efficiency of Uniform Tuned Liquid Column Damper (UTLCD) in structures resting on loose soils, considering soil-structure interaction was investigated. The soil beneath the structure is loose sandy soil. The Laminar Shear Box (LSB) as a soil container was adopted and the scaled form of the prototype structure namely model structure using scaling laws was built. Applying selected earthquake record the top story displacement of the soil-structure model was obtained. In the rest of the tests, the soil-structure model was equipped with UTLCD and tested. 3 different in sizes of UTLCDs, each with different blocking ratio and frequencies was used. To implement tests, completely randomized factorial design, with factors of Blocking ratio, Frequency and Type of the UTLCD was adopted. Through statistical analysis of the experimental tests was demonstrated that the mentioned factors are effective in response of the structure. Using Response Surface Methodology (RSM), the optimum values of the factors to minimize the top story displacement has been found. In this study it was demonstrated that, due to low reduction in structural responses (in average 12 percent), the optimum UTLCD is not efficient enough in controlling structures resting on loose soils.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Performance Study of Tuned Liquid Column Ball Damper for Excessive Liquid Displacement on Response Reduction of Structure

The tuned liquid column damper (TLCD) having a uniform cross-sectional tube of U-shaped, occupied with liquid is used as a vibrational response mitigation device. The tuned liquid column ball damper (TLCBD) is a modified TLCD, where, an immovable orifice, positioned at the middle part of the horizontal portion, is replaced by a metal ball. Different studies on the unconstrained optimization per...

متن کامل

Numerical and Experimental Study of Soil-structure Interaction in Structures Resting on Loose Soil Using Laminar Shear Box

In the present work, the effect of Soil-Structure Interaction (SSI) in low frequency structures resting on loose soil, through numerical modelling and shaking table tests have been studied. In theoretical studies two types of models namely fixed base and flexible base structure were subjected to three selected earthquake records. Nonlinear dynamic analysis was employed for all of the numerical ...

متن کامل

OPTIMIZED TUNED LIQUID COLUMN DAMPERS FOR EARTHQUAKE OSCILLATIONS OF HIGH-RISE STRUCTURES INCLUDING SOIL EFFECTS

This paper investigates the optimized parameters for the tuned liquid column dampers to decrease the earthquake vibrations of high-rise buildings. Considering soil effects, the soilstructure interaction (SSI) is involved in this model. The Tuned Liquid Column Damper (TLCD) is also utilized on the roof of the building. Since the TLCD is a nonlinear device, the time domain analysis based on nonli...

متن کامل

The Effect of Tuned Mass Damper on Seismic Response of Building Frames with Uncertain Structural Characteristics

Tuned mass dampers (TMDs) could be used to absorb the input energy of the applied load, and reduce the response of the building frames. However, the effectiveness of TMD in reducing the response of the building frames could be affected by inherited uncertainties in the structural characteristics of the frames. In this study, in order to investigate the probabilistic response of steel moment-res...

متن کامل

Closed Form Optimal Solution of a Tuned Liquid Column Damper Responding to Earthquake

In this paper the vibration behaviors of a structure equipped with a tuned liquid column damper (TLCD) under a harmonic type of earthquake loading are studied. However, due to inherent nonlinear liquid damping, it is no doubt that a great deal of computational effort is required to search the optimum parameters of the TLCD, numerically. Therefore by linearization the equation of motion of the s...

متن کامل

a study on thermodynamic models for simulation of 1,3 butadiene purification columns

attempts have been made to study the thermodynamic behavior of 1,3 butadiene purification columns with the aim of retrofitting those columns to more energy efficient separation schemes. 1,3 butadiene is purified in two columns in series through being separated from methyl acetylene and 1,2 butadiene in the first and second column respectively. comparisons have been made among different therm...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 31  شماره 7

صفحات  1028- 1037

تاریخ انتشار 2018-07-01