Experimental Evaluation of Depth Dose by Exit Surface Diode Dosimeters for Off-Axis Wedged Fields in Radiation Therapy

نویسندگان

  • Alireza Mohammadkarim Department of Medical Radiation Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran Ph.D student, Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
  • Alireza Shirazi Department of Medical Physics, Tehran University of Medical Sciences, Tehran, Iran
  • Ghazale Geraily Department of Medical Physics, Tehran University of Medical Sciences, Tehran, Iran
  • Hasan Ali Nedaie Department of Radiotherapy, Oncology and Medical Physics, Tehran University of Medical Sciences, Tehran, Iran
  • Mahbod Esfehani Department of Radiation Oncology, Cancer Institute of Iran, Tehran University of Medical Sciences, Tehran, Iran
  • Mahmoud Allahverdi Department of Medical Physics, Tehran University of Medical Sciences, Tehran, Iran
چکیده مقاله:

Introduction Evaluation of the delivered dose of externally wedged photon beams by external diode dosimeters during the treatment process requires the estimation of exit surface dose correction factors in various wedge angles and field sizes. Materials and Methods A system of absorbed dose evaluation, using p-type diode dosimeters placed on the exit surface of a phantom, was characterized for externally wedged photons with the maximum square field size. The values of wedge correction factor on the exit surface of the polystyrene phantom were determined for 60Co and 6 MV photons. Then, the wedge correction factors were estimated at desirable depths. Results Based on the findings, the deviation of off-axis wedge correction factors of the exit surface wedged fields from the central axis factor may be as large as ±10% at the evaluated depths. The results showed that the absorbed dose at each depth of patient tissue could be estimated by applying an accurate exit wedge correction factor for that particular depth, with negligible probable errors (below 1.5%). Conclusion In case positioning a diode dosimeter on the patient’s entrance surface of a phantom of patients is troublesome, the diode dosimeter can be placed on the exit surface in order to evaluate the absorbed dose for externally wedged photons. Based on the findings, exit dose correction factors for wedged beams cannot be discarded; in fact, these factors are variable at different directions of externally wedged beams.  

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

experimental evaluation of depth dose by exit surface diode dosimeters for off-axis wedged fields in radiation therapy

introduction evaluation of the delivered dose of externally wedged photon beams by external diode dosimeters during the treatment process requires the estimation of exit surface dose correction factors in various wedge angles and field sizes. materials and methods a system of absorbed dose evaluation, using p-type diode dosimeters placed on the exit surface of a phantom, was characterized for e...

متن کامل

Quantitative measurements for entrance and exit radiation dose confirmation for cancer patients: An analysis of large cohort of patients

Background: The success of radiation therapy depends on accurate dose delivery to the target. Diode in vivo measurement of entrance and exit dose is a valuable quality assurance (QA) tool to ensure accurate dose delivery.  Materials and Methods: This study was performed at BINO Cancer Hospital, Bahawalpur. Entrance and exit dose measurements were done with p-type diode for various types of canc...

متن کامل

A new method for ideal dose distribution of two adjacent fields for external beam radiation therapy

 Abstract Background: Adjacent treatment fields are commonly used in external beam radiation therapy, such as mantle and inverted-Y fields for the treatment of Hodgkin’s disease and craniospinal fields used in the treatment of medulloblastoma and head and neck tumors when the lateral neck fields are placed adjacent to the anterior supraclavicular field. In each of these situations, there is a p...

متن کامل

Measurement of skin surface dose distributions in radiation therapy using poly(vinyl alcohol) cryogel dosimeters

In external beam radiation therapy (EBRT), skin dose measurement is important to evaluate dose coverage of superficial target volumes. Treatment planning systems (TPSs) are often inaccurate in this region of the patient, so in vivo measurements are necessary for skin surface dose estimation. In this work, superficial dose distributions were measured using radiochromic translucent poly(vinyl alc...

متن کامل

Absorbed Dose Calculation In Irregular Blocked Radiation Fields: Evaluation of Clarkson’s Sector Integration Method for Radiation Fields Commonly Used in Conventional Radiotherapy

Introduction: Irregular/blocked fields are routinely used in radiotherapy. The doses of these fields are usually calculated by means of equivalent square method that is inherently prone to uncertainty. On the other hand, Clarkson’s sector integration method is a dose calculation method which offers far better accuracy in dose calculation of irregular fields. The Scatter Air Ratio (SAR) of an in...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 12  شماره 4

صفحات  262- 270

تاریخ انتشار 2015-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023