Experimental and Computational Study on Hydrodynamic of a Downscaled Mini Vessel USP Dissolution Test Apparatus II
نویسندگان
چکیده مقاله:
Although not listed on the United States Pharmacopeia (USP), like standard USP 2, small volume USP 2 dissolution apparatus has gained a great deal of attention, especially for cases where small amount of drug product is available for testing in research and design step or evaluations are to be made on a tablet containing trace amounts of the active pharmaceutical ingredient. In this work, firstly, small volume USP 2 apparatus was designed and manufactured using downscaling rules and considering standard USP 2 as a reference. Then, velocity profile, flow patterns, and shear rate were obtained by PIV and COMSOL simulation software at paddle speeds of 66 and 133 rpm, corresponding to agitation speed of 50 and 100 rpm, respectively, in the standard USP 2. Comparison between experimental and computational results showed acceptable adaptation. Instantaneous velocity data showed eddies and secondary flows in different zones of the vessel, which is desirable for micro-mixing but undesirable in terms of system consistency and reproducibility, as sampling from these zones are known to lead to inconsistent data. Furthermore, increased agitation rate led to the disappearance of rotational zones around the paddle. The magnitude of velocity and shear rate increased by 35% with an increment of paddle stirring from 66 to 133 rpm.
منابع مشابه
Calibration—the Usp Dissolution Apparatus Suitability Test
This report summarizes some trends observed in drug dissolution testing, based upon the United States Pharmacopeia (USP) dissolution Apparatus Suitability Test results and the preliminary data obtained from an international collaborative study to assess the pharmaceutical quality of furosemide products in different countries. Based on the USP calibrator data submitted by the participants, repre...
متن کاملSuppository Dissolution Utilizing USP Apparatus
Standardized in-vitro dissolution testing of suppositories has been of interest to the pharmaceutical industry since the early works of Giabaldi and Gundhofer in 1975.(1) Anthony Palmieri exam ined standard izin g suppository dissolutions in his work at the University of Wyoming (2). Palmieri developed a slotted dissolution basket for suppositories that is ---------widely used by many individua...
متن کاملEvaluation of Moonpool Effects on Hydrodynamic Resistance of a Supply Vessel, Using Experimental and Numerical Methods
Moonpool is an opening in the floor or base of a hull ship which can be used to lower tools and vehicles into the sea in a protected area. In this paper, the effect of a rectangular cross section moonpool on the resistance force of a supply vessel was investigated both by experimental and numerical methods. For both methods a 1:37.2 scale of Caspian3 surface vessel was used. Experiments were ca...
متن کاملthe relationship between eq, iq and test format: a study on test fairness
the major aim of this study was to investigate the relationship between iq, eq and test format in the light of test fairness considerations. this study took this relationship into account to see if people with different eq and iq performed differently on different test formats. to this end, 90 advanced learners of english form college of ferdowsi university of mashhad were chosen. they were ask...
15 صفحه اولHydrodynamic Complexity Induced by the Pulsing Flow Field in USP Dissolution Apparatus 4
USP dissolution Apparatus 4 can have a pulsing or non-pulsing flow, with most commercial apparatus employing a pulsing flow. Overall, a low velocity flow field is present, particularly in the larger 22.6-mm diameter cell. Dissolution data, computational fluid dynamics (CFD), and imaging methods are used and discussed to investigate the effects of low velocity pulsing flow on dissolution. Local ...
متن کاملconstruction and validation of a computerized adaptive translation test (a receptive based study)
آزمون انطباقی رایانه ای (cat) روشی نوین برای سنجش سطح علمی دانش آموزان می باشد. در حقیقت آزمون های رایانه ای با سرعت بالایی به سمت و سوی جایگزین عملی برای آزمون های کاغذی می روند (کینگزبری، هاوسر، 1993). مقاله حاضر به دنبال آزمون انطباقی رایانه ای برای ترجمه می باشد. بدین منظور دو پرسشنامه مشتمل بر 55 تست ترجمه میان 102 آزمودنی و 10 مدرس زبان انگلیسی پخش گردید. پرسشنامه اول میان 102 دانشجوی س...
منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 16 شماره 3
صفحات 3- 22
تاریخ انتشار 2019-09-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023