Evaluation of the effective dose during PBFT for brain cancer: A Monte Carlo Study
نویسندگان
چکیده مقاله:
Introduction: Recently, an approach exploiting the proton therapy biological enhancement by using Boron atoms injected inside a tumor, has been proposed. Three alpha particles with an average energy around 4MeV are emitted from the point of reaction between a proton and boron. In addition, the 719 keV prompt gamma emitted by the proton Boron fusion reactions can be used for on-line proton beam imaging purposes. Materials and Methods: We simulated a proton beam passing through the Snyder head phantom with and without a boron uptake region (BUR) in the tumor to investigate the amplification of the proton’s maximum dose level using a Monte Carlo simulation. The proton’s maximum dose level obtained for different proton energies with considering distinction physical conditions (i.e. location and thickness of BUR, boron concentration). The percentage depth dose (PDD) of the proton in the Snyder phantom without the BUR obtained using the F6 tally. However, the counting of additional proton by alpha particle is based on the results by using F4 tally. The absorbed dose due to three alpha particle and proton components acquired for scalp, skull, tumor and brain. Results: The aim of this study is to compare the effectiveness between proton boron fusion therapy (PBFT) and proton therapy and to analyze dose escalation using a Monte Carlo simulation in the brain cancer. When the portion of the proton’s maximum dose (Bragg- peak) is included at tumor region, which is BUR, observed a dramatic therapy effect with less damage to normal tissue. The peak value of maximum dose level when the boron particle was accurately labeled at the region was 185% among the energies. Conclusion: The PDD of the proton beam from the Snyder phantom including the BURs shows more efficient than that of conventional proton therapy on tumor region. The utility of PBFT was verified using the simulation and it has a potential for application in radiotherapy. When the portion of the proton’s maximum dose (Bragg-peak) is included at tumor region, which is BUR, observed a dramatic therapy effect with less damage to normal tissue.
منابع مشابه
Monte Carlo calculations of dose distribution for the treatment of gastric cancer with proton therapy
Proton therapy is a common form of external radiation therapy based on the manipulation of Bragg peak of this beam, it can treat the tumor by delivering high levels of doses to it, while protecting surrounding healthy tissues against radiation. In this work, the dose distribution of proton and secondary particles such as neutrons, photons, electrons and positrons in gastric cancer proton therap...
متن کاملMonte Carlo Evaluation of Gamma Knife Dose Profile in Real Brain Phantom
Introduction The Gamma Knife system is designed solely for non-invasive treatment of brain disorders, and it benefits from stereotactic surgical techniques. Dose calculations required in the system are performed by GammaPlan code; in this code, brain tissue is considered uniform. In the present study, we evaluated the effect of Gamma Knife system on the obtained dose through simulating a real ...
متن کاملA Monte Carlo Study for Photoneutron Dose Estimations around the High-Energy Linacs
Background: High-energy linear accelerator (linac) is a valuable tool and the most commonly device for external beam radiation treatments in cancer patients. In the linac head, high-energy photons with energies above the threshold of interaction produce photoneutrons. These photoneutrons deliver the extra dose to the patients in the planning treatment and increase the risk of secondary cancer.O...
متن کاملEvaluation of Lung Dose in Esophageal Cancer Radiotherapy Using Monte Carlo Simulation
Background and purpose: Radiation therapy make an important contribution in the control and treatment of cancers. Lungs are the main organs at risk in esophageal cancer radiotherapy. Difference between the dose distribution due to the treatment planning system (TPS) and the patient's body dose is dependent on the calculation of the treatment planning system algorithm, which is more pronounced i...
متن کاملEvaluation of X-ray absorbed dose in thyroid during CXR imaging of the chest by Monte Carlo simulation (DOSXYZnrc)
Abstract: Introduction: Chest radiography is one of the most common X-ray imaging procedures performed worldwide. During this process, in addition to the chest, other tissues, including the thyroid, are also exposed to radiation. Due to the fact that one of the most important risk factors for thyroid cancer is ionizing radiation, measuring the absorption of X- rays in the thyroid is of spec...
متن کاملEvaluation of Organ Specific peripheral dose for Gamma knife 4C based on Monte Carlo
Introduction: Stereotactic Gamma Knife radiosurgery has been widely used for treating brain tumors. The scattered radiation outside of treatment field (peripheral dose) can induce the secondary cancer to specific organ. This paper investigated the absorbed dose to eyes, thyroid, heart, lung, breast and colon using a Monte Carlo technique for Mird phantom. We also study the ef...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 15 شماره Special Issue-12th. Iranian Congress of Medical Physics
صفحات 308- 308
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023