Evaluation of the accuracy of two apex locators in endodontic treatment and retreatments: an ex vivo study
نویسندگان
چکیده مقاله:
Introduction: Working length determination is important in successful endodontic treatment and retreatment.This study evaluated the accuracy of two electronic apex locators Root ZX and Raypex®6 (EALs) in determining the electronic working length (EWL) of the root canals in endodontic treatment and retreatment. Materials and Methods: Access cavities were prepared on forty extracted, single-rooted human teeth and the actual working length (AWL) of the canals was determined. In the first phase of the study, primary EWL of un-instrumented teeth was measured and compared between two EALs. In phase II, all of the teeth were pre-flared and divided into the control(n=10) and the retreatment groups (n=30). Canals in the retreatment group were obturated by the lateral condensation technique using Gutta percha and sealer. After 15 days, gutta-percha was removed, and then the secondary EWL was recorded and compared between the two devices, in treatment and retreatment groups. Data were analysed by paired t-test and t-test. Results: Significant differences were found between both EALs in treatment and retreatment phases of the study (p<0.001).both EALs showed increased accuracy in retreatment group (p<0.001). However, no statistically significant differences were found between the control and retreatment groups in the second phase of the study for Root ZX (p = 0.929), and Raypex®6 (p=0.937). Conclusion: Accuracy of the two EALs was similar and acceptable. EWLs determined by Root ZX were closer to the AWL. The EWL determination after pre-flaring improved the accuracy of EALs and root canal obturation remnant materials did not have any clear effect on the accuracy of these EALs.
منابع مشابه
Accuracy of three electronic apex locators in anterior and posterior teeth: an ex vivo study.
INTRODUCTION The aim of this study was to determine in anterior teeth, bicuspids, and molars (1) the accuracy of 3 different electronic apex locators (EALs) in detecting the apical foramen and (2) the accuracy of digital radiography in determining the working length (WL), compared with visible control under a microscope. METHODS By using radiovideography (RVG), we measured the lengths of 120 ...
متن کاملAn in vivo radiographic evaluation of the accuracy of Apex and iPex electronic Apex locators.
The aim of this study was to evaluate in vivo the clinical applicability of two electronic apex locators (EALs) - Apex (Septodont) and iPex (NSK) - in different groups of human teeth by using radiography. The working lengths (WLs) of 100 root canals were determined electronically. The EAL to be used first was chosen randomly and a K-file was inserted into the root canal until the EAL display in...
متن کاملAccuracy of three electronic apex locators compared with digital radiography: an ex vivo study.
INTRODUCTION This study compared (1) the accuracy of three different electronic apex locators (EALs) in detecting the apical foramen ex vivo under clinical conditions; (2) the accuracy of digital radiography and EALs in determining the working length (WL) with visible control under a microscope; and (3) the precision of #10, #15, and #20 K-files in electronic measurements. METHODS The length ...
متن کاملa case study of the two translators of the holy quran: tahereh saffarzadeh and laleh bakhtiar
بطورکلی، کتاب های مقدسی همچون قران کریم را خوانندگان میتوان مطابق با پیش زمینه های مختلفی که درند درک کنند. محقق تلاش کرده نقش پیش زمینه اجتماعی-فرهنگی را روی ایدئولوژی های مترجمین زن و در نتیجه تاثیراتش را روی خواندن و ترجمه آیات قرآن کریم بررسی کند و ببیند که آیا تفاوت های واژگانی عمده ای میان این مترجمین وجود دارد یا نه. به این منظور، ترجمه 24 آیه از آیات قرآن کریم مورد بررسی مقایسه ای قرار ...
15 صفحه اولEx vivo evaluation of the accuracy of two electronic apex locators during root canal length determination in primary teeth.
AIM To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. METHODOLOGY One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the ac...
متن کاملEvaluation of Root Canal Morphology and Root Apex Anatomy of Mandibular Premolars in an Iranian Population: an ex-vivo study
Objectives Adequate knowledge about canal anatomy is necessary for clinicians to prevent any damage to the periodontium. The aim of this study was to evaluate the canal and apical complexities of the mandibular first and second premolars in an Iranian population. Methods One-hundred mandibular first (n=50) and second (n=50) premolars were collected. After access cavity preparation, 2% methylen...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 5 شماره None
صفحات 21- 28
تاریخ انتشار 2016-03
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023