Evaluation of Seismic Response of Concrete Structures Reinforced by Shape Memory Alloys (Technical Note)
نویسندگان
چکیده مقاله:
Shape memory alloys (SMAs) are unique smart materials that have many advantages, such as ability to resist large strains without leaving residual strains and ability to recover original form. However, the high costs of SMAs have limited their usage. This paper evaluates the behavior of concrete structures equipped with SMAs in an optimal manner as they are being used along the plastic hinge of the beams. For this purpose, a reinforced concrete (RC) beam, a 2D RC frame and a 3D RC building are considered, which were tested in previous studies under cyclic loading and on a shaking table. After verifying RC beam in the Seismostruct software, the steel rebars are replaced by SMAs in all connections of models and time history analysis is performed. The seismic response of concrete structures equipped with SMAs is compared with the conventional RC structures. The maximum base shear and roof displacement, amount of residual displacement and distribution of interstory drift at the structure height are among the factors to be evaluated. The results show that, due to the use of SMAs in concrete structures, the maximum base shear does not significantly change compared with the conventional RC structures, and the residual displacements in the structure roof have been reduced. On the other hand, the maximum displacement of the roof was increased in the structures with SMAs. The concrete structures equipped with SMAs experience a slight residual deformation, and the distribution of interstory drift is even more uniform at the height of such structures.
منابع مشابه
Application of Shape Memory Alloys in Seismic Isolation: A Review
In the last two decades, there has been an increasing interest in structural engineering control methods. Shape memory alloys and seismic isolation systems are examples of passive control systems that use of any one alone, effectively improve the seismic performance of the structure. Characteristics such as large strain range without any residual deformation, high damping capacity, excellent re...
متن کاملThe Effect of Axial Force Variations on Nonlinear Modeling and Seismic Response of Reinforced Concrete Structures
In order to increase the accuracy of evaluating seismic response of structures, it is critical to conduct dynamic analyses based upon precise nonlinear models being as consistent as possible with the real conditions of corresponding structures. The concentrated plasticity model including one elastic element and two nonlinear spring elements at both ends has been considered within the research c...
متن کاملSeismic Response of Reinforced Concrete Columns
There are a large number of reinforced concrete buildings in seismically active areas of the world that are not built in accordance with modern seismic design provisions such as those published by American Concrete Institution ([ACI] Committee 318, 2008). In the United States and other parts of the developed world, these buildings were constructed between 1930s to mid 1970s according to the bui...
متن کاملSeismic Response Control Using Shape Memory Alloys: A Review
Shape memory alloys (SMAs) are a class of alloys that possess numerous unique characteristics. They offer complete shape recovery after experiencing large strains, energy dissipation through hysteresis of response, excellent resistance to corrosion, high fatigue resistance and high strength. These features of SMAs which can be exploited for the use in control of civil structures subjected to se...
متن کاملapplication of shape memory alloys in seismic isolation: a review
in the last two decades, there has been an increasing interest in structural engineering control methods. shape memory alloys and seismic isolation systems are examples of passive control systems that use of any one alone, effectively improve the seismic performance of the structure. characteristics such as large strain range without any residual deformation, high damping capacity, excellent re...
متن کاملShear Capacity of Reinforced Concrete Flat Slabs Made with High-strength Concrete: A Numerical Study of the Effect of Size, Location, and Shape of the Opening (TECHNICAL NOTE)
Nowadays, concrete with strength higher than 50 MPa is utilized due to the ever increasing need for higher strength and prolonged healing properties. Despite the widespread use of high-strength concrete, only a few research projects have been conducted on the punching shear strength of high-strength concrete slabs. Reinforced concrete flat slabs are widely employed in structural systems. The lo...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 33 شماره 3
صفحات 410- 418
تاریخ انتشار 2020-03-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023